Time relay

Action

  • SPST
    (3)
  • DPST
    (1)

Adjustable time / Full-scale value

  • 100.00 h s
    (1)

Adjustable time / initial value

  • 0.05 s
    (1)

Ambient temperature / during operation / maximum

  • 60 C
    (1)

Ambient temperature / during operation / minimum

  • -25 C
    (1)

Ambient temperature / during storage / maximum

  • 85 C
    (3)

Ambient temperature / during storage / minimum

  • -40 C
    (2)

Ambient temperature / during transport / maximum

  • 85 C
    (2)

Ambient temperature / during transport / minimum

  • -40 C
    (2)

Ampacity / of the bridge terminals / maximum

  • 10 A
    (1)

AWG number / as coded connectable conductor cross section / solid / maximum

  • 12
    (1)

AWG number / as coded connectable conductor cross section / solid / minimum

  • 20
    (1)

Category / acc. to EN 954-1

  • none
    (3)

Conducted interference / due to burst / acc. to IEC 61000-4-4

  • 2kVnetworkconnection/1kVcontrolconnection
    (3)

Conducted interference / due to conductor-conductor surge / acc. to IEC 61000-4-5

  • 1kV
    (3)

Conducted interference / due to conductor-earth surge / acc. to IEC 61000-4-5

  • 2kV
    (3)

Contact Rating

  • R300 / B300
    (12)
  • B300 / R300
    (1)
  • 120 V
    (1)
  • 208 V
    (1)
  • 240 V
    (2)

Contact reliability / of auxiliary contacts

  • oneincorrectswitchingoperationof100millionswitchingoperations(17V,5mA)
    (1)

Control supply voltage / 1 / at AC / at 50 Hz / Final rated value

  • 240 V
    (1)

Control supply voltage / 1 / at AC / at 50 Hz / Initial rated value

  • 24 V
    (1)
  • 12 V
    (1)

Control supply voltage / 1 / at AC / at 60 Hz / Initial rated value

  • 12 V
    (1)

Control supply voltage frequency / 1 / Final rated value

  • 60 Hz
    (1)

Degree of pollution

  • 3
    (3)

Depth

  • 74 mm
    (1)
  • 90 mm
    (8)

Design of the fuse link / for short-circuit protection of the auxiliary switch / required

  • fusegL/gG:4A
    (3)

Design of the thread / of the connection screw

  • M3
    (2)

Electrical endurance (switching cycles) / at AC-15 / at 230 V / typical

  • 100000
    (1)

Electrostatic discharge / acc. to IEC 61000-4-2

  • 4kVcontactdischarge/8kVairdischarge
    (3)

Enclosure

  • IP20
    (13)

Environmental Conditions

  • 85 -40 C
    (13)
  • 80 -40 C
    (2)

Field-bound parasitic coupling / acc. to IEC 61000-4-3

  • 10V/m
    (3)

Height

  • 38 mm
    (1)
  • 100 mm
    (8)

Influence of the surrounding temperature

  • 1%inthewholetemperaturerangetothesetruntime
    (2)

Installation altitude / at height above sea level / maximum

  • 2000 m
    (2)

Material / of switching contacts

  • AgSnO2
    (2)

Mechanical service life (switching cycles) / typical

  • 10000000
    (1)

Mounting

  • screw and snap-on mounting onto 35 mm standard mounting rail any
    (13)
  • clip-on any (like contactor)
    (2)
  • Remote
    (3)

mounting position

  • any
    (3)

Mounting type

  • screwandsnap-onmountingonto35mmstandardmountingrail
    (1)

Number of CO contacts / delayed switching

  • 2
    (1)

Number of Poles

  • 1
    (3)
  • 2
    (1)

Operating current / of auxiliary contacts / at DC-13 / at 125 V

  • 0.2 A
    (1)

Operating current / of auxiliary contacts / at DC-13 / at 24 V

  • 1 A
    (1)

Operating current / of auxiliary contacts / at DC-13 / at 250 V

  • 0.1 A
    (1)

Operating Cycles

  • 10M
    (14)
  • 100000000
    (1)

Operating range factor control supply voltage rated value / at DC / Full-scale value

  • 1.1
    (1)

Operating range factor control supply voltage rated value / at DC / initial value

  • 0.85
    (1)

Operating Temperature

  • 60.0 -25.0 C
    (9)
  • 60.0 -25.0 C
    (2)
  • 50 - 90 DEG F
    (4)

Power loss [V?A] / at AC / maximum

  • 3.35 VA
    (1)

Power loss [W] / total / typical

  • 2 W
    (1)

Power supply influence

  • 1%inthewholevoltagerangetothesetruntime
    (2)

Product category

  • Furtheraccessories
    (1)

Product component / Relay output

  • Yes
    (1)

Product designation

  • Screwadapterforcontactors,sizeS0/S2
    (1)
  • timingrelay
    (2)

Product extension / optional / remote control

  • No
    (1)

Product extension / required / remote control

  • No
    (1)

Product function / at the relay outputs / Switchover delayed/without delay

  • No
    (1)

Protection against electrical shock

  • finger-safe
    (2)

Protection class IP

  • IP20
    (1)

Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750

  • K
    (1)

Reference code / acc. to DIN EN 61346-2

  • K
    (1)

Reference code / acc. to DIN EN 81346-2

  • K
    (1)

Relative humidity / during operation / maximum

  • 95 %
    (1)

Relative humidity / during operation / minimum

  • 10 %
    (1)

Resistance

  • 4000
    (4)

Standard

  • FCC
    (4)

Surge voltage resistance / rated value

  • 4000 V
    (1)

Switching capacity current / with inductive load / maximum

  • 3 A
    (2)

Switching capacity current / with inductive load / minimum

  • 0.01 A
    (1)

Switching function / flashing asymmetrically starting with pulse

  • No
    (2)

Switching function / ON-delay

  • Yes
    (2)

Switching function / passing make contact

  • No
    (2)

Switching function / passing make contact/instantaneous contact

  • No
    (1)

Switching function / with control signal / additive ON delay

  • No
    (2)

Switching function / with control signal / passing break contact

  • No
    (2)

Switching function / with control signal / pulse-shaping

  • No
    (1)

Test voltage / for isolation test

  • 2.5 kV
    (2)

Thermal current

  • 5 A
    (1)

Tightening torque / maximum

  • 0.8 N.m
    (2)

Tightening torque / minimum

  • 0.6 N.m
    (2)

Timing Range

  • 45 (Average) S
    (4)

Type

  • 3RP20 Timing Relay
    (4)
  • 3RP15 Timing Relay
    (9)
  • 3RA Accessory
    (2)
  • Low Voltage
    (4)

Type of connectable conductor cross-sections / at AWG conductors / solid

  • 1x(20...12),2x(20...14)
    (1)

Type of connectable conductor cross-sections / at AWG conductors / stranded

  • 1x(20...12),2x(20...14)
    (1)

Type of connectable conductor cross-sections / finely stranded / with core end processing

  • 1x(0.5...4mm),2x(0.5...1.5mm)
    (1)

Type of connectable conductor cross-sections / for auxiliary contacts / solid

  • 2x(0.5...2.5mm),1x4mm
    (1)

Type of connectable conductor cross-sections / solid

  • 1x(0.5...4.0mm),2x(0.5...2.5mm)
    (1)

Type of electrical connection / for auxiliary and control current circuit

  • screw-typeterminals
    (2)

Type of insulation

  • Basicinsulation
    (2)

Type of voltage / of the control supply voltage

  • AC/DC
    (3)

Vibration resistance / acc. to IEC 60068-2-6

  • 10...55Hz/0.35mm
    (2)

Width

  • 45 mm
    (1)
  • 17.5 mm
    (4)
  • 22.5 mm
    (4)

Manufacturers