Overload relay

ambient temperature / during operation / max.

  • 60 C
    (4)

Ambient temperature / during operation / maximum

  • 70 C
    (23)
  • 60 C
    (18)

ambient temperature / during operation / min.

  • -25 C
    (2)

Ambient temperature / during operation / minimum

  • -20 C
    (6)
  • -40 C
    (16)
  • -25 C
    (19)

Ambient temperature / during storage / maximum

  • 80 C
    (30)

Ambient temperature / during storage / minimum

  • -40 C
    (15)
  • -55 C
    (33)

Ambient temperature / during transport / maximum

  • 80 C
    (29)

Ambient temperature / during transport / minimum

  • -40 C
    (16)
  • -55 C
    (34)

Application area

  • forinverse-timedelayedprotectionofloadswithnormalstartingagainstexcessivetemperaturerisesduetooverloadorphasefailure
    (12)
  • forinverse-timedelayedprotectionofloadswithnormalandheavystartingagainstexcessivetemperaturerisesduetooverload,phaseunbalanceorphasefailure
    (6)

Arrangement of electrical connectors / for main current circuit

  • Topandbottom
    (17)

AWG number / as coded connectable conductor cross section / for main contacts / maximum

  • 8
    (5)
  • 12
    (2)
  • 1
    (6)

AWG number / as coded connectable conductor cross section / for main contacts / minimum

  • 18
    (12)
  • 16
    (1)
  • 20
    (4)
  • 10
    (8)

Certificate of suitability / according to ATEX directive 2014/34/EU

  • DMT98ATEXG001
    (14)
  • PTB09ATEX3001
    (3)

Certificate of suitability / relating to ATEX

  • DMT98ATEXG001
    (9)
  • PTB09ATEX3001
    (4)
  • onrequest
    (2)

Conducted interference / due to burst / acc. to IEC 61000-4-4

  • 2kV(powerports),1kV(signalports)correspondstodegreeofseverity3
    (9)

Conducted interference / due to conductor-conductor surge / acc. to IEC 61000-4-5

  • 1kV(linetoline)correspondstodegreeofseverity3
    (8)

Conducted interference / due to conductor-earth surge / acc. to IEC 61000-4-5

  • 2kV(linetoearth)correspondstodegreeofseverity3
    (7)

Conducted interference / due to high-frequency radiation / acc. to IEC 61000-4-6

  • 10Vinfrequencyrange0.15to80MHz,modulation80%AMwith1kHz
    (6)

Connectable conductor cross-section / for main contacts / solid / maximum

  • 10 mm2
    (1)
  • 50 mm2
    (1)
  • 16 mm2
    (3)

Connectable conductor cross-section / for main contacts / solid / minimum

  • 0.5 mm2
    (2)
  • 1 mm2
    (1)
  • 2.5 mm2
    (3)

Connectable conductor cross-section / for main contacts / stranded / maximum

  • 70 mm2
    (3)

Connectable conductor cross-section / for main contacts / stranded / minimum

  • 6 mm2
    (3)

Contact Configuration

  • nc
    (3)
  • no/nc
    (7)
  • 1NC 1NO
    (95)

Contact Rating

  • B600/R300
    (10)
  • B600 / R300
    (74)
  • B300 / R300
    (21)

Contact rating / of auxiliary contacts / according to UL

  • B600/R300
    (13)

Depth

  • 90 mm
    (7)
  • 73 mm
    (4)
  • 80 mm
    (20)
  • 79 mm
    (21)
  • 70 mm
    (31)
  • 84 mm
    (9)
  • 85 mm
    (26)
  • 95 mm
    (13)
  • 109 mm
    (14)
  • 124 mm
    (25)
  • 104 mm
    (8)
  • 105 mm
    (22)
  • 117 mm
    (16)
  • 125 mm
    (11)
  • 140 mm
    (8)

Derating factor / for rated value of the operating current / at between 60C and 70C

  • 0.87
    (8)

Derating factor / for rated value of the operating current / up to 60 C

  • 1
    (13)

Design of screwdriver shaft

  • Diameter5to6mm
    (5)
  • Diameter5...6mm
    (3)
  • Hexagonalsocket
    (2)

Design of the auxiliary switch

  • integrated
    (16)

Design of the fuse link / for short-circuit protection of the auxiliary switch / required

  • fusegG:6A,quick:10A
    (9)
  • fusegG:6A
    (3)

Design of the overload release

  • thermal
    (13)
  • electronic
    (8)

Design of the thread / of the connection screw / for main contacts

  • M4
    (1)
  • M3
    (1)
  • M6
    (4)
  • M8
    (2)

Design of the thread / of the connection screw / of the auxiliary and control contacts

  • M3
    (6)

Display version / for switching status

  • Slideswitch
    (7)

Electrostatic discharge / acc. to IEC 61000-4-2

  • 6kVcontactdischarge/8kVairdischarge
    (5)

EMC emitted interference / acc. to IEC 60947-1

  • CISPR11,environmentB(residentialarea)
    (8)

EMI immunity / acc. to IEC 60947-1

  • correspondstodegreeofseverity3
    (8)

Environmental Conditions

  • 80 -40 C
    (48)
  • 80.0 -50.0 C
    (56)

Failure rate [FIT] / with low demand rate / acc. to SN 31920

  • 50 FIT
    (16)

Field-bound parasitic coupling / acc. to IEC 61000-4-3

  • 10V/m
    (6)

Full Load Current Range

  • Heaters
    (3)
  • 13 to 52 A
    (1)
  • 50 to 200 A
    (1)
  • 25 to 100 A
    (1)
  • 0.75 to 3.4 A
    (1)
  • 5.5 to 22 A
    (1)
  • 10 to 40 A
    (1)
  • 3 to 12 A
    (1)

Full-load current (FLA) / for three-phase AC motor / at 480 V / rated value

  • 3.2 A
    (1)
  • 0.5 A
    (1)
  • 1 A
    (1)
  • 5 A
    (1)
  • 80 A
    (1)
  • 20 A
    (1)
  • 32 A
    (2)
  • 45 A
    (1)
  • 73 A
    (2)
  • 50 A
    (2)

Full-load current (FLA) / for three-phase AC motor / at 600 V / rated value

  • 4 A
    (1)
  • 0.2 A
    (1)
  • 80 A
    (2)
  • 20 A
    (1)
  • 32 A
    (2)
  • 45 A
    (1)
  • 73 A
    (1)
  • 50 A
    (1)
  • 99 A
    (1)

Height

  • 72 mm
    (7)
  • 79 mm
    (4)
  • 89 mm
    (20)
  • 102 mm
    (25)
  • 76 mm
    (23)
  • 85 mm
    (15)
  • 97 mm
    (6)
  • 114 mm
    (7)
  • 87 mm
    (13)
  • 109 mm
    (11)
  • 99 mm
    (8)
  • 81 mm
    (8)
  • 90 mm
    (22)
  • 105 mm
    (27)
  • 106 mm
    (23)
  • 120 mm
    (8)

Installation altitude / at height above sea level / maximum

  • 2000 m
    (35)

Insulation voltage / with degree of pollution 3 / rated value

  • 690 V
    (23)
  • 300 V
    (2)
  • 1000 V
    (16)

Internal diameter / of the usable ring cable lug / minimum

  • 3.2 mm
    (3)
  • 6.3 mm
    (2)

Load

  • B600 / R300
    (1)

Maximum Motor Voltage

  • 600v
    (10)

Maximum Switching Voltage

  • 600v
    (10)

Mounting

  • direct
    (3)
  • direct/DIN Rail
    (7)
  • direct mounting any
    (93)
  • stand-alone installation any
    (2)
  • vertical and direct mounting
    (7)
  • direct mounting / stand-alone installation any
    (9)

mounting position

  • any
    (8)

Mounting type

  • Contactormounting
    (7)
  • stand-aloneinstallation
    (2)

MTTF / with high demand rate

  • 2280 a
    (4)

MTTF / with low demand rate

  • 130 s
    (5)

Number of NC contacts / for auxiliary contacts

  • 1
    (27)

Number of NC contacts / for auxiliary contacts / Note

  • forcontactordisconnection
    (13)

Number of NO contacts / for auxiliary contacts

  • 1
    (20)

Number of NO contacts / for auxiliary contacts / Note

  • formessage"Tripped"
    (14)

Number of Poles

  • 3
    (136)

Number of poles / for main current circuit

  • 3
    (39)

Operating current / at AC-3 / at 400 V / Rated value

  • 2.50 A
    (1)
  • 25.00 A
    (2)
  • 12.00 A
    (1)
  • 4.00 A
    (1)
  • 0.40 A
    (1)
  • 0.32 A
    (1)
  • 50.00 A
    (9)
  • 80.00 A
    (2)
  • 60.00 A
    (2)
  • 20.00 A
    (1)
  • 40.00 A
    (1)
  • 45.00 A
    (1)
  • 65.00 A
    (2)
  • 73.00 A
    (1)
  • 63.00 A
    (2)
  • 115.00 A
    (5)
  • 75.00 A
    (1)
  • 90.00 A
    (1)
  • 100.00 A
    (2)

Operating current / for heavy starting CLASS 20 / maximum

  • 50 A
    (1)

Operating current / for heavy starting CLASS 30 / maximum

  • 50 A
    (2)

Operating current / of auxiliary contacts / at AC-15 / at 110 V

  • 3 A
    (12)
  • 4 A
    (3)

Operating current / of auxiliary contacts / at AC-15 / at 120 V

  • 3 A
    (12)
  • 4 A
    (5)

Operating current / of auxiliary contacts / at AC-15 / at 125 V

  • 3 A
    (10)
  • 4 A
    (4)

Operating current / of auxiliary contacts / at AC-15 / at 230 V

  • 2 A
    (13)
  • 3 A
    (4)

Operating current / of auxiliary contacts / at AC-15 / at 24 V

  • 3 A
    (9)
  • 4 A
    (4)

Operating current / of auxiliary contacts / at AC-15 / at 400 V

  • 1 A
    (14)

Operating current / of auxiliary contacts / at AC-15 / at 600 V

  • 0.75 A
    (13)

Operating current / of auxiliary contacts / at AC-15 / at 690 V

  • 0.75 A
    (12)

Operating current / of auxiliary contacts / at DC-13 / at 110 V

  • 0.22 A
    (11)
  • 0.3 A
    (3)

Operating current / of auxiliary contacts / at DC-13 / at 125 V

  • 0.22 A
    (7)
  • 0.3 A
    (3)

Operating current / of auxiliary contacts / at DC-13 / at 220 V

  • 0.11 A
    (12)

Operating current / of auxiliary contacts / at DC-13 / at 24 V

  • 2 A
    (16)

Operating current / of auxiliary contacts / at DC-13 / at 60 V

  • 0.55 A
    (18)
  • 0.3 A
    (9)

Operating current / rated value

  • 1.25 A
    (1)
  • 0.25 A
    (1)
  • 50 A
    (3)
  • 80 A
    (1)
  • 20 A
    (1)
  • 32 A
    (2)
  • 45 A
    (1)
  • 73 A
    (2)
  • 115 A
    (1)

Operating frequency / rated value / maximum

  • 60 Hz
    (12)

Operating frequency / rated value / minimum

  • 50 Hz
    (14)

Operating power / at AC-3 / at 400 V / rated value

  • 0.75 k kW
    (1)
  • 1.50 k kW
    (1)

Operating power / at AC-3 / at 500 V / rated value

  • 1.50 k kW
    (1)

Operating power / at AC-3 / at 690 V / rated value

  • 37.00 k kW
    (1)
  • 0.09 k kW
    (1)
  • 0.25 k kW
    (1)

Operating power / for AC motors / at 500 V / at 50 Hz / maximum

  • 2.2 kW
    (1)
  • 5.5 kW
    (2)
  • 0.12 kW
    (1)
  • 55 kW
    (1)
  • 30 kW
    (2)
  • 75 kW
    (1)

Operating power / for AC motors / at 500 V / at 50 Hz / minimum

  • 15 kW
    (1)
  • 11 kW
    (2)
  • 22 kW
    (1)

Operating power / for AC motors / at 690 V / at 50 Hz / maximum

  • 75 kW
    (1)
  • 45 kW
    (2)
  • 90 kW
    (1)

Operating power / for AC motors / at 690 V / at 50 Hz / minimum

  • 0.55 kW
    (1)
  • 18.5 kW
    (1)
  • 11 kW
    (2)
  • 30 kW
    (1)

Operating power / for three-phase motors / at 400 V / at 50 Hz / maximum

  • 22 kW
    (2)
  • 55 kW
    (1)

Operating power / for three-phase motors / at 400 V / at 50 Hz / minimum

  • 0.37 kW
    (1)
  • 7.5 kW
    (1)
  • 18.5 kW
    (1)

Operating Temperature

  • 60.0 -25.0 C
    (48)
  • 70.0 -20.0 C
    (56)
  • -40 ?C and 70 ?C
    (6)

Operating voltage / acc. to UL 60947 / rated value

  • 600 V
    (11)

Operating voltage / at AC-3 / Rated value / maximum

  • 690 V
    (18)
  • 1000 V
    (2)

Operating voltage / for remote-reset function / at DC

  • 24 V
    (1)

Operating voltage / rated value

  • 690 V
    (10)
  • 1000 V
    (1)

Outer diameter / of the usable ring cable lug / maximum

  • 7.5 m
    (1)
  • 19 m
    (1)

Power loss [W] / for rated value of the current / at AC / in hot operating state

  • 9.6
    (1)
  • 4.8
    (2)
  • 0.1
    (2)
  • 0.2
    (1)
  • 10.5
    (1)
  • 15.6
    (4)
  • 21
    (1)
  • 0.9
    (1)
  • 13.5
    (1)

Power loss [W] / total / typical

  • 0.1 W
    (3)
  • 6.2 W
    (1)
  • 4.3 W
    (1)
  • 5.1 W
    (1)
  • 0.6 W
    (2)
  • 0.2 W
    (3)
  • 1.8 W
    (1)
  • 4.6 W
    (6)
  • 11 W
    (2)
  • 13 W
    (1)
  • 0.9 W
    (2)

Product component / Auxiliary switch

  • Yes
    (16)

Product component / RESET button

  • Yes
    (9)

Product component / STOP pushbutton

  • Yes
    (5)
  • No
    (3)

Product component / Trip indicator

  • Yes
    (14)

Product designation

  • thermaloverloadrelay
    (24)
  • solid-stateoverloadrelay
    (6)
  • Functionexpansionmoduleoverloadrelay
    (1)

Product function / Ground fault detection

  • No
    (16)

Product function / overload protection

  • Yes
    (17)

Product function / overload warning

  • No
    (17)

Product function / Phase failure detection

  • Yes
    (20)

Product function / removable terminal for auxiliary and control circuit

  • No
    (21)
  • Yes
    (15)

Product type designation

  • 3RU2
    (15)
  • 3RB3
    (3)

Protection against electrical shock

  • finger-safe
    (3)
  • finger-safewhentouchedverticallyfromfrontacc.toIEC60529
    (6)

Protection class IP / of the terminal

  • IP20
    (6)
  • IP00
    (11)

Protection class IP / on the front

  • IP20
    (19)

Rated operational voltage Ue

  • 1000 V
    (2)
  • 690 V
    (4)

Recovery time / after overload trip / with automatic reset / typical

  • 3 min
    (2)
  • 10 min
    (3)

Recovery time / after overload trip / with manual reset

  • 10 min
    (4)
  • 0 min
    (1)

Recovery time / after overload trip / with remote-reset

  • 0 min
    (3)
  • 10 min
    (4)

Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750

  • F
    (4)

Reference code / acc. to DIN EN 61346-2

  • F
    (5)

Reference code / acc. to DIN EN 81346-2

  • F
    (14)

Relative humidity / during operation / maximum

  • 95 %
    (16)
  • 90 %
    (17)

Relative humidity / during operation / minimum

  • 10 %
    (18)
  • 0 %
    (5)

Required spacing / for grounded parts / at the side

  • 6 mm
    (8)
  • 10 mm
    (2)

Required spacing / for grounded parts / Backwards

  • 0 mm
    (10)

Required spacing / for grounded parts / downwards

  • 0 mm
    (5)
  • 6 mm
    (2)
  • 10 mm
    (3)

Required spacing / for grounded parts / forwards

  • 0 mm
    (8)
  • 6 mm
    (1)
  • 10 mm
    (3)

Required spacing / for grounded parts / upwards

  • 6 mm
    (4)
  • 10 mm
    (3)
  • 0 mm
    (4)

Required spacing / for live parts / at the side

  • 6 mm
    (7)
  • 10 mm
    (4)

Required spacing / for live parts / Backwards

  • 0 mm
    (9)

Required spacing / for live parts / downwards

  • 6 mm
    (2)
  • 10 mm
    (4)
  • 0 mm
    (4)

Required spacing / for live parts / forwards

  • 6 mm
    (2)
  • 0 mm
    (5)
  • 10 mm
    (4)

Required spacing / for live parts / upwards

  • 6 mm
    (2)
  • 10 mm
    (5)
  • 0 mm
    (4)

Required spacing / with side-by-side mounting / at the side

  • 6 mm
    (2)
  • 0 mm
    (5)
  • 10 mm
    (1)

Required spacing / with side-by-side mounting / Backwards

  • 0 mm
    (13)

Required spacing / with side-by-side mounting / downwards

  • 6 mm
    (4)
  • 0 mm
    (6)
  • 10 mm
    (1)

Required spacing / with side-by-side mounting / forwards

  • 0 mm
    (10)
  • 10 mm
    (1)

Required spacing / with side-by-side mounting / upwards

  • 6 mm
    (4)
  • 0 mm
    (7)
  • 10 mm
    (2)

Reset current / for remote-reset function / maximum

  • 200 mA
    (1)

Reset Type

  • auto/manual
    (3)
  • auto/manual/remote
    (7)
  • 3
    (7)

Response time / of the ground fault protection / in settled state

  • 1000 ms
    (1)

Response value current / of the ground fault protection / minimum

  • 0.75xIMotor
    (2)

Shock resistance

  • 15g/11ms
    (2)
  • 8g/11ms
    (1)

Shock resistance / acc. to IEC 60068-2-27

  • 8g/11ms
    (11)
  • 15g/11ms
    (4)

Shock resistance / acc. to IEC 60068-2-27 / Note

  • Signalingcontact97/98inposition"Tripped":9g/11ms
    (1)
  • Signalingcontact97/98inposition"Tripped":8g/11ms
    (3)

Size of contactor / can be combined / company-specific

  • S00
    (9)
  • S0
    (6)
  • S2
    (11)
  • S3
    (6)

Size of overload relay

  • S00
    (2)
  • S0
    (2)
  • S2
    (9)
  • S3
    (5)

Size of the screwdriver tip

  • PozidrivPZ2
    (10)
  • 3,0x0,5mm
    (1)
  • 4mmhexagonsocket
    (2)

Standard

  • cUL, CSA
    (10)
  • CSA/UL
    (7)

Surge voltage resistance / rated value

  • 6 V
    (18)
  • 8 V
    (16)

T1 value / for proof test interval or service life / acc. to IEC 61508

  • 20 a
    (9)

Temperature compensation / maximum

  • 60 C
    (10)

Temperature compensation / minimum

  • -40 C
    (4)
  • -25 C
    (1)

Thermal current

  • 4 A
    (1)
  • 32 A
    (1)
  • 50 A
    (2)
  • 115 A
    (1)

Tightening torque / for auxiliary contacts / for ring cable lug / maximum

  • 0.8 N.m
    (1)

Tightening torque / for auxiliary contacts / with screw-type terminals / maximum

  • 1.2 N.m
    (2)

Tightening torque / for auxiliary contacts / with screw-type terminals / minimum

  • 0.8 N.m
    (3)

Tightening torque / for main contacts / for ring cable lug / maximum

  • 2 N.m
    (2)
  • 6 N.m
    (3)

Tightening torque / for main contacts / for ring cable lug / minimum

  • 2.5 N.m
    (1)
  • 4.5 N.m
    (1)

Tightening torque / for main contacts / with screw-type terminals / maximum

  • 4.5 N.m
    (1)
  • 6 N.m
    (3)

Tightening torque / for main contacts / with screw-type terminals / minimum

  • 3 N.m
    (1)
  • 4.5 N.m
    (2)

Trip Class

  • CLASS10
    (170)
  • CLASS10E
    (33)
  • CLASS20E
    (32)
  • CLASS5E,10E,20Eand30Eadjustable
    (9)
  • Class5,10,20and30adjustable
    (4)
  • CLASS10A
    (8)

Trip Type

  • mechanical
    (3)
  • electronic
    (7)

Type

  • Bi-Metalic Overload Relay
    (3)
  • Solid State Overload Relay
    (7)
  • 3RB2 SS Overload Relay
    (48)
  • 3RU2 thermal overload relay
    (63)

Type of connectable conductor cross-sections / at AWG conductors / for auxiliary contacts

  • 2x(20...14)
    (5)
  • 2x(20...16),2x(18...14)
    (3)

Type of connectable conductor cross-sections / at AWG conductors / for main contacts

  • 1x(20...12)
    (2)
  • 2x(18...2),1x(18...1)
    (5)
  • 2x(10...1/0),1x(10...2/0)
    (2)

Type of connectable conductor cross-sections / for auxiliary contacts / solid

  • 1x(0.5...4mm),2x(0.5...2.5mm)
    (3)
  • 2x(0.25...1.5mm)
    (2)

Type of connectable conductor cross-sections / for main contacts / solid

  • 1x(1...50mm),2x(1...35mm)
    (1)
  • 2x(2.5...16mm)
    (3)

Type of connectable conductor cross-sections / for main contacts / stranded

  • 1x10mm
    (2)
  • 2x(6...16mm),2x(10...50mm),1x(10...70mm)
    (3)

Type of electrical connection / for auxiliary and control current circuit

  • screw-typeterminals
    (6)
  • ringcableconnection
    (1)
  • spring-loadedterminals
    (5)

Type of electrical connection / for main current circuit

  • screw-typeterminals
    (16)
  • Ringcablelugconnection
    (5)
  • spring-loadedterminals
    (5)

Type of protection

  • Exe
    (8)
  • onrequest
    (2)
  • II(2)G[Exe][Exd][Expx]II(2)D[Ext][Exp]
    (3)

Type of protection / according to ATEX directive 2014/34/EU

  • ExII(2)G[Exe][Exd][Expx];ExII(2)D[Ext][Exp]
    (5)
  • ExII(2)GD
    (14)

Type of voltage / for auxiliary and control current circuit

  • AC/DC
    (16)

Type of voltage / for main current circuit

  • AC/DC
    (10)
  • AC
    (7)

Type of voltage supply / via input/output link master

  • No
    (4)

Vibration resistance

  • 1-6Hz,15mm;6-500Hz,20m/s;10cycles
    (4)

Width

  • 45 mm
    (131)
  • 55 mm
    (54)
  • 70 mm
    (42)

Manufacturers

All
ABB - Electrification

Products from this Category