Manufacturer:
Approval
BRAND/SERIES NAME
- Series FF (31)
- Series T100 (32)
- Series DTAV40 (2)
- Series E1000 (2)
- Series FD (36)
- Series GM40AV (4)
- Series P1100 (3)
- Series P1200 (2)
- Series PB (1)
- Series PF1100 (5)
- Series PF1200 (1)
- Series R8800 (3)
- Series T10000R (7)
- Series T1400 (4)
- Series T170 (10)
- Series T1800 (1)
- Series T1900 (4)
- Series T1970 (6)
- Series T2000 (2)
- Series T21000R (2)
- Series T30000R (4)
- Series T40000R (4)
- Series T7000B (7)
- Series T8800 (3)
- Series TN311 (1)
- Series WHAVQ (1)
Application
- Fan, Lighting, Motor, Heater (67)
- Indoor, Post Lantern, Sign, Pool Heater, Filter, Hydro chlorinator, Air Conditioning, Blower, Electric Fence, Pump, Heating/Ventilating System, Music and Signal System, Fan, Poultry Fogger, Conveyer (3)
- Ventilating Fans, Fogging Equipment, Process Equipment, Poultry and Livestock Feeders, Spraying Equipment (1)
- Medium and Low-Temperature Commercial Refrigeration Systems (2)
- Turning on Lights, Fans, Pumps, and Other Heavy Duty Loads (2)
- Lighting Control, Access Control, Commercial Refrigeration, General Electrical Circuits, Pumps, Motors, Fan Control (4)
- Ground Pool Pumps, Lights, Fountains (2)
- Pumps, Cleaners (1)
- Pool/Spa Equipment Used in Cold Climates (4)
- Filter Pumps, Filter Pump Booster Pump, Fountains, Combinations, Pool-Spa Combinations (2)
- Multi-Station Hydro-Indexing Valves, Greenhouses, Lawn Sprinklers, Irrigation Control, Drip Irrigation Systems (6)
- Pool/Spa Equipment, Lights (7)
- Low-Voltage Lighting (4)
- Indoor/Outdoor Lighting, Signs, Filters, Electric Fences, Fans, Conveyers, Pool Heaters, Blowers, Pumps (18)
- Booster Pump, Lighting, Hydrochlorinator, Fan, Air Conditioning, Music and Signal System, Heat Pump, Swimming Pool/Spa Filter Pump with Gas Fired Heater (8)
- Indoor/Outdoor Lighting, Post Lantern, Sign, Pool Heater, Filter, Hydro chlorinator, Air Conditioning, Blower, Electric Fence, Pump, Heating/Ventilating System, Music and Signal System, Fan, Poultry Fogger, Conveyer (2)
- Residential, Institutional, Industrial, Commercial, Military Facilities, Schools (2)
- Pool/Spa Pump with Gas Fired Heater (1)
- Commercial, Industrial, Residential, Indoor/Outdoor Lighting, Signs, Filters, Electric Fences, Fans, Conveyers, Pool Heaters, Blowers, Pumps (15)
- Blower, Dairy Equipment, Fan, Filter, Heater, Oil Well Pump, Poultry Fogger, Poultry Feeder, Process Equipment, Recorded Music, Silo Unloader (10)
- Oil Well Pumps, Silo Unloaders, Process Equipment (1)
- Air Conditioning, Defrost Control, Fan, Heating, Light, Motor, Pump, Ventilating (2)
- Pumps, Lighting (4)
- Pumps, Lighting, Cleaning Systems, Security Systems, Fountains, Sprinkler Systems (2)
- Heating, Air Conditioning, Pump, Indoor Lighting, Outdoor Lighting, Motor, Sign, Billboard, Ventilating System, Fan, Filter, 3-Phase Load (7)
- Residential Electric Hot Water Heater (1)
- Residential, Commercial Electric Water Heater (1)
- Air Conditioning, Exhaust Fan, Heat Lamp, Lighting, Spas, Saunas, Ventilating, Whirlpool (3)
Color
Contact Current Rating
- 20 Ampere at 125 VAC 50/60 Hz (Resistive), 10 Ampere at 250/277 VAC 50/60 Hz (Resistive), 7 Ampere at 125 VAC (Tungsten) (10)
- 20 Ampere at 125 VAC 50/60 Hz, 10 Ampere at 250/277 VAC 50/60 Hz (Resistive), 7 Ampere at 125 VAC 50/60 Hz (Tungsten) (57)
- 20 Ampere at 125 VAC 60 Hz, 10 Ampere at 250/277 VAC 60 Hz, 7 Ampere at 125 VAC (Tungsten) (3)
Contact Power Rating
Current Rating
- 40 Ampere at 120 to 480 VAC (Resistive), 40 Ampere at 120 to 277 VAC (Tungsten/Inductive) (5)
- 20 Ampere at 240 VAC 60 Hz (General), 20 Ampere at 120/240 VAC, 28 VDC 60 Hz (Resistive), 5 Ampere at 240 VAC 60 Hz (Tungsten), 10 Ampere at 277 VAC 60 Hz (1)
- 40 Ampere at 120 to 240 VAC (Resistive) (2)
- 15 Ampere (5)
- 40 Ampere at 120 to 277 VAC (Resistive), 15 Ampere at 120 VAC (Tungsten), 30 Ampere at 120 VAC (Ballast), 20 Ampere 277 VAC (Ballast) (NO)/30 Ampere at 120 to 277 VAC (Resistive), 2 Ampere at 120 VAC (Tungsten), 10 Ampere 277 VAC (Ballast) (NC) (4)
- 15 Ampere (Resistive/Tungsten) (4)
- 20 Ampere (Resistive) (3)
- 20 Ampere at 120 to 277 VAC (1)
- 30 Ampere at 120/208/240 VAC (Resistive/Inductive/Tungsten), 92 Ampere at 120/240 VAC, 168 Ampere at 120/208 VAC 60 Hz (Power Center) 1-Phase (2)
- 30 Ampere (3)
- 30 Ampere at 120/208/240 VAC (Resistive/Inductive/Tungsten) (5)
- 30 Ampere at 120/208/240 VAC (Resistive/Inductive/Tungsten), 62 Ampere at 120/240 VAC, 109 Ampere at 120/208 VAC 60 Hz (Power Center) 1-Phase (2)
- 40 Ampere (Resistive/Inductive/Tungsten), 16 Ampere at 277 VAC (Ballast) (18)
- 40 Ampere (Resistive/Inductive/Tungsten), 16 Ampere at 277 VAC (Ballast), 10 Ampere at 240 VAC (Heater Control Circuit) (9)
- 40 Ampere (2)
- 40 Ampere (Resistive/Tungsten/Inductive), 16 Ampere at 277 VAC (Ballast) (4)
- 40 Ampere (Resistive/Tungsten), 16 Ampere at 277 VAC (Ballast) (11)
- 20 Ampere at 125 to 480 VAC (Resistive) (11)
- 30 Ampere at 120/208/240 VAC (Resistive/Inductive/Tungsten), 60 Ampere at 120/240/208 VAC 60 Hz (Loadcenter) 1-Phase (2)
- 30 Ampere at 120/208/240 VAC (Resistive/Inductive/Tungsten), 100 Ampere at 120/240/208 VAC 60 Hz (Loadcenter) 1-Phase (6)
- 30 Ampere at 120/208/240 VAC (Resistive/Inductive/Tungsten), 125 Ampere at 120/240/208 VAC 60 Hz (Loadcenter) 1-Phase (2)
- 40 Ampere at 120 to 480 VAC (Resistive), 40 Ampere at 120/208/240/277 VAC (Inductive/Tungsten), 16 Ampere at 277 VAC (Ballast) (6)
- 40 Ampere at 120 to 480 VAC (Resistive), 40 Ampere (Tungsten/Inductive) (1)
- 25 Ampere (1)
- 40 Ampere Resistive at 250 VAC (NO), 30 Ampere Resistive at 250 VAC (NC) (1)
Enclosure
Finish
Material
Maximum Number of Operations
Maximum OFF Time
Maximum ON Time
Minimum OFF Time
Minimum ON Time
Mounting
Operating Temperature
Operation Type
Power Rating
- 2 HP at 120 VAC (24 FLA) (3)
- 5 HP at 240 VAC 1-Phase (28 FLA) (2)
- 1 HP at 120 VAC, 2 HP at 240 VAC 60 Hz (Motor), 470 VA at 240 VAC 60 Hz (Pilot Duty) (1)
- 1 HP (16 FLA, 96 LRA) at 120 VAC, 2 HP (12 FLA, 72 LRA) at 240 VAC (2)
- 1800 W, 12 FLA (Motor) (2)
- 1 HP (16 FLA, 90 LRA) at 120 VAC, 2 HP (12 FLA, 52 LRA) at 208 to 277 VAC (NO), 1 HP (12 FLA, 30 LRA) at 120 VAC, 2 HP (10 FLA, 30 LRA) at 240 VAC (NC), 300 VA (Pilot Duty) at 120 to 240 VAC (4)
- 1 HP, 1800 W (Resistive/Tungsten) (2)
- 1 HP (1)
- 1800 W (Resistive/Tungsten), 1 HP (15 FLA, 90 LRA) at 120 VAC (2)
- 1250 W at 125 VAC (Tungsten), 1 HP (16 FLA) at 120 VAC, 2 HP (12 FLA) at 240 VAC (Motor), 360 VA (Pilot Duty) at 120 to 240 VAC (1)
- 3 HP (4)
- 1.5/3 HP (2)
- 3 HP, 2 HP (24 FLA) at 120 VAC, 5 HP (28 FLA) at 240 VAC (Motor), 1000 VA (Pilot Duty) at 120/208/240 VAC (2)
- 1-1/2 HP (1)
- 2 HP (24 FLA) at 120 VAC, 5 HP (28 FLA) at 240 VAC, 1000 VA (Pilot Duty) at 120/208/240 VAC (17)
- 2 HP (24 FLA) at 120 VAC, 5 HP (28 FLA) at 240 VAC, 1000 VA (Pilot Duty) (18)
- 2 HP (24 FLA) at 120 VAC, 5 HP (28 FLA) at 240 VAC, 1000 VA at 120 to 277 VAC (Pilot Duty) (19)
- 10000 W (Resistive) (2)
- 2 HP (24 FLA) at 120 VAC, 5 HP (28 FLA) at 240 VAC 1-Phase, 7-1/2 HP (28 FLA) at 208 VAC, 10 HP (28 FLA) at 240 VAC 3-Phase (7)
- 2 HP (24 FLA) at 120 VAC, 1000 VA (Pilot Duty) at 120 to 277 VAC (1)
- 1/2 HP at 125 VAC, 1 HP at 250 VAC (12)
- 1/2 HP at 120 VAC, 1 HP at 240 VAC (1)
- 2 HP (24 FLA) at 120 VAC, 5 HP (28 FLA) at 240 VAC 1-Phase, 7-1/2 HP (28 FLA) at 208 VAC, 10 HP (28 FLA) at 240 VAC 3-Phase, 1000 VA (Pilot Duty) at 120 to 277 VAC (4)
- 1/2 HP (2)
- 20 VA (1)
- 1/3 HP, 1875 W (Tungsten) (1)
- 6250 W (Resistive) (1)
- 10000 W (NO), 7500 W (NC) (1)
Reserve Power
Size
- 1-3/4 Inch W x 1-1/4 Inch D x 4-1/8 Inch H (67)
- 5 Inch W x 3 Inch D x 7-3/4 Inch H (3)
- 5-1/8 Inch W x 3-7/16 Inch D x 7-7/8 Inch H (23)
- 3-1/4 Inch W x 1-3/8 Inch D x 4-1/4 Inch H (2)
- 6.61 Inch W x 3 Inch D x 8.88 Inch H (4)
- 5-3/8 Inch W x 2-1/2 Inch D x 5-3/8 Inch H (2)
- 3-5/8 Inch W x 3-1/4 Inch D x 5-3/8 Inch H (1)
- 5-1/2 Inch W x 4 Inch D x 9-3/8 Inch H (2)
- 2-13/16 Inch W x 1-61/64 Inch D x 3-1/3 Inch H (1)
- 5-3/4 Inch W x 3-5/8 Inch D x 9-5/8 Inch H (4)
- 12-7/8 Inch W x 4-1/4 Inch D x 12 Inch H (2)
- 6-1/2 Inch W x 4 Inch D x 10 Inch H (18)
- 10-7/8 Inch W x 4-3/4 Inch D x 12-7/8 Inch H (5)
- 12-7/8 Inch W x 4-3/4 Inch D x 12-7/8 Inch H (2)
- 5-1/2 Inch W x 3-5/8 Inch D x 9-3/8 Inch H (2)
- 6-1/2 Inch W x 3-5/8 Inch D x 10-1/8 Inch H (17)
- 8-7/8 Inch W x 4-3/4 Inch D x 16-7/8 Inch H (2)
- 10-7/8 Inch W x 4-3/4 Inch D x 16-7/8 Inch H (4)
- 12-7/8 Inch W x 4-3/4 Inch D x 20-7/8 Inch H (4)
- 9 Inch W x 3-3/4 Inch D x 13-1/8 Inch H (6)
- 8-1/4 Inch W x 4 Inch D x 12-1/2 Inch H (1)
- 3 Inch W x 2 Inch D x 3-1/8 Inch H (1)
- 1.8 Inch W x 1.85 Inch D x 4.2 Inch H (3)
Switch Type
Type
Voltage Rating
- 125 VAC at 60 Hz (30)
- 208 to 277 VAC at 60 Hz (26)
- 120 to 240 VAC at 60 Hz (2)
- 120/240 VAC at 60 Hz (1)
- 120 VAC at 60 Hz (17)
- 120 to 277 VAC at 60 Hz (3)
- 120 to 277 VAC at 50/60 Hz (2)
- 240 VAC (8)
- 120/240 VAC (2)
- 240 VAC at 60 Hz (7)
- 120/120 VAC at 60 Hz (1)
- 240/240 VAC at 60 Hz (5)
- 208 to 250 VAC at 60 Hz (2)
- 480 VAC at 60 Hz (5)
- 240/120 VAC at 60 Hz (1)
- 24 VAC at 60 Hz (1)
- 208 to 240 VAC (1)