Power supply units
Power supply units
Amperage Rating
-
10 A(3)
-
4 A(1)
-
2.5 A(1)
-
5 A(1)
-
3 A(1)
-
40 A(1)
-
20 A(2)
-
20 AMP(2)
-
Output 1: 12 V @ 1 A or 15 V @ 0.8 A. Output 2: -12 V @ 1A or -15 V @ 0.8 A(1)
-
0.4, 0.25(1)
-
0.4, 0.25 AMP(1)
-
1.1, 0.7 AMP(1)
-
0.6, 0.33 AMP(2)
-
0.8 AMP(1)
-
6 AMP(4)
-
2.5 AMP(3)
-
0.6 AMP(2)
-
1.2 AMP(3)
-
1 AMP(2)
-
3 AMP(4)
-
2 AMP(1)
-
1.3 AMP(1)
-
1.3/0.7 AMP(2)
-
2.2/1.0 AMP(1)
-
5/2 AMP(1)
-
N/A(7)
-
5 V @ 3 A(2)
-
Output 1: 12 V @ 1.8 A or 15 V @ 1.5 A. Output 2: -12 V @ 1.8 A or -15 V @1.5 A(2)
-
Output 1: 5 V @ 3 A . Output 2: -12 V @ 1.5 A(1)
-
Output 1: 15 V @ 3 A . Output 2: -15 V @ 3 A(1)
-
Output 1: 12 V @ 3.4 A . Output 2: -12 V @ 3.4 A(1)
-
Output 1: 5 V @ 6 A . Output 2: -2 V @ 3.4 A(1)
-
1.8 AMP(1)
-
3.3/1.7(1)
-
30 AMPS(1)
-
2.2, 1.2 AMP(1)
-
1.8, 1 AMP(1)
-
1.65 - 0.55(1)
-
1.65 - 0.55 AMP(1)
-
3 x 0.9 or 2 x 1.3(1)
-
3.8 AMP(1)
-
4/2.3 AMP(1)
-
3 x 0.8 or 2 x 1.2 AMP(1)
-
3 x 0.5 or 2 x 0.7 AMP(1)
-
3 x 1.6 AMP(1)
-
3.8 A(1)
-
1.25 A(1)
Cable Size
-
16 -10 AWG Solid, 16 - 12 AWG Stranded AWG(2)
-
20 to 12 Solid or Stranded AWG(7)
-
16 to 10 AWG Solid, 16 to 12 AWG Flexible(1)
-
16 - 10 AWG Solid AWG(8)
-
16 to 10 AWG Solid, 16 to 12 AWG Flexible AWG(1)
-
16 - 10 AWG Solid(4)
-
20 to 12 Solid or Stranded(1)
-
Use UL 758 wire rated min. 24 V, VW-1/FT-1, max. 3.05 m.(3)
-
Input Connector size range: 16-12 AWG (1.5-3.3 mm2) for solid conductors; Output Connector size range: 16-12 AWG (1.5-3.3 mm2) for solid conductors(1)
-
Input Connector size range: 22-12 AWG (0.4-3.4 mm2) for solid conductors; Output Connector size range: 20-12 AWG (0.5-3.4 mm2) for solid conductors(3)
Connection
-
Conduit Knockouts for side entry to wiring compartment(1)
-
Terminals(1)
Connector
-
Screw Terminal Connections, 10-16 AWG, IP20(1)
Control
-
DC OK Relay(2)
Efficiency
-
83 PCT(1)
-
80 PCT(3)
-
86 PCT(1)
-
90 PCT(1)
-
70 PCT(2)
-
75 PCT(3)
-
77 PCT(3)
-
68 PCT(8)
-
62 PCT(2)
-
87.5 PCT(2)
-
88 PCT(6)
-
84(1)
-
88(7)
-
93(1)
-
70% Typical at full load(4)
-
75% Typical at full load(5)
-
80% Typical at full load(1)
-
91.2 PCT(1)
-
85 PCT(1)
-
94 PCT(1)
-
85(1)
-
>87%(2)
-
79(1)
Enclosure
-
NEMA 3R, Class 1 Div 2 Group A,B,C and D(1)
-
Class 1, IP20 AWG(1)
-
Class 1, IP20(7)
-
Class 1 Zone 2, IP20(4)
-
IP20(18)
-
Case H2(1)
-
NEMA 4/12(1)
-
Case B2(1)
-
Case C(4)
-
Case A(3)
-
Case I2(4)
-
Case K(1)
-
Case B1(2)
-
Case L(1)
-
Case F(2)
-
Case G2(1)
-
NEMA 3R with optional weather shield (WS-15)(1)
-
Metal(1)
-
Nema 4X, IP66/67(1)
-
IP66/67 Versatile Protection, UL50 Type4X(3)
-
To be installed in an enclosure(5)
Environmental Conditions
-
90 RH Humidity Range PCT(19)
-
-25 to +65 DEG C Operating Temp(18)
-
90 RH Humidity Range(4)
-
110 RH Humidity Range PCT(1)
-
Full power to 50 DEG C. Derated operation to 70 DEG C(1)
-
10 to 95 Relative Humidity(1)
-
-25 to 70 C(2)
-
To be installed in a controlled environment(5)
Frequency Rating
-
47-63 Hz(5)
-
60 HZ(2)
-
47/63 HZ(7)
-
47 to 63 HZ(18)
-
50/60 HZ(31)
-
47 - 63 HZ(5)
-
47 to 63(2)
-
N/A(2)
-
Refer to Primary Voltage(1)
-
47/63(1)
-
43 - 67 HZ(1)
-
50/60/400 HZ(1)
-
47-63, 400 +/- 40 HZ(6)
Fuse Rating
-
2.0 A Slow Fuse(19)
-
Internally Fused(23)
-
Non-Replicable Internal Fuse(1)
-
Internally fused; fuses not replaceable.(3)
Height
-
2 IN(3)
-
4.88 IN(6)
-
2.95 IN(10)
-
1.37 IN(6)
-
1.29 IN(12)
-
4.88(3)
-
4(2)
-
17 IN(1)
-
5.62 IN(3)
-
4.87 IN(11)
-
3.99 IN(3)
-
4.92 IN(1)
-
4 IN(1)
-
5.63 IN(1)
-
2.95(1)
-
4.85(3)
-
1.8 IN(2)
-
2.2 IN(2)
-
1.5 IN(2)
-
1.14 IN(1)
-
1.69 IN(1)
-
5(1)
-
5 in(1)
-
3.27 in(1)
-
4.84 in(1)
Input
-
240, Single Phase V(1)
Input Voltage
-
120/208/240/277 Volt Primary VAC(1)
-
240/480, 230/460, 220/440 Volt Primary(1)
Insulation
-
UL Class 200 DEG C Insulation System(1)
-
UL Class 180 DEG C Insulation System(1)
-
Class 180 DEG C Insulation System(1)
-
220 DEG Insulation System(1)
KVA Rating
-
1 kVA(1)
-
25 KVA(1)
Length
-
11 IN(2)
-
4.73 IN(2)
-
4.63 in(2)
-
3.52 in(3)
-
4.55 IN(5)
-
7 IN(5)
-
1.77 IN(4)
-
0.9 IN(1)
-
3.5 IN(1)
-
4.43 IN(6)
-
4.72 IN(11)
-
3.26 IN(1)
-
6.5(1)
-
9 IN(8)
-
4.87 IN(3)
-
4.84 IN(3)
-
13.98 IN(1)
-
16.85 IN(1)
-
10.25(1)
-
10.25 IN(1)
-
6.38 IN(1)
-
2.85(1)
-
2.85 IN(2)
-
16 IN(1)
-
1.97 IN(1)
-
4.56 IN(1)
-
6.54 IN(1)
-
6.4 IN(2)
-
8.5 IN(2)
-
5 IN(3)
-
4.36 IN(1)
-
7.36 IN(1)
-
4.66 IN(1)
Material
-
Metal Housing(14)
-
Molded Plastic(8)
-
Case Material/Potting: UL94-VO(19)
-
Metal(3)
-
Plastic(3)
Maximum Input Current
-
5.4 AMP(1)
Maximum Output Current
-
12.5/6.25 AMP(1)
Mounting
-
DIN Rail(28)
-
DIN Rail/Chassis(20)
-
Chassis(1)
-
Mtg Width 5.31, Mtg Depth 4.25, Slot Size .31 x .69 IN(1)
-
Wall Mounting Brackets Available(1)
-
Chassis with tabs(1)
-
Chassis Mounted Using Integral Mounting Tabs(3)
Number Of Receptacles
-
2(3)
-
5(1)
Number Of Taps
-
6(1)
-
None(1)
Output Voltage
-
120/240 Volt Secondary VAC(1)
-
120/115/110 Volt Secondary(1)
Phase
-
1(12)
-
3(5)
-
Three(4)
-
Single(2)
Primary Voltage
-
240 x 480 Volt Primary, 120 Volt Secondary, 60Hz; 230 x 460 Volt Primary, 115 Volt Secondary, 50/60 HZ; 220 x 440 Volt Primary, 110 Volt Secondary, 50/60 HZ(1)
-
120/208/240/277 VAC(1)
Receptacle Configuration
-
Input/3 Pole Male - Output 4 Pole Female(1)
-
Input: 3-PIN IP67 molded plug (quick disconnect). Output: 4-PIN IP67 molded receptacle(2)
-
Input: 3-PIN IP67 molded plug (quick disconnect). Outputs: Four @ 4-PIN IP67 molded receptacle (2 per 100W)(1)
Secondary Voltage
-
Refer to Primary Voltage(1)
-
120/240 VAC(1)
Standard
-
CE(2)
-
cULus Listed: E25872, E77014, UL 1561 or UL 506, CSA C22.2 No. 47 or No. 66(1)
-
UL (CANADA AND US), UL 94, UL 508, UL 60950, CUL, CSA-C22.2, CE(7)
-
UL (CANADA AND US), UL 508, UL 60950, CUL, CSA-C22.2, CE(10)
-
UL Recognized Component, ITE, E137632, CE: IEC/EN 60950-1, 2nd Edition(18)
-
Not Listed(6)
-
cULus Listed: E77014, UL 506, CSA C22.2 No. 66, RoHS Compliant(1)
-
UL Recognized Component, ITE, UL 60950-1, CSA Certified, ITE CSA C22.2 CSA 60950-1, CE, IEC60950-1(24)
-
UL Recognized Component , CSA Certified, CE(3)
-
UL Listed: E77014, UL 506; CSA Certified: LR-14328-4, CSA C22.2 No. 66. RoHS Compliant(1)
-
cULus Recognized Component: UL 1449, 3rd Edition, Type 4 locations, UL 1283, CSA C22.2 No. 8; CE rated: EN 61643-11:2002, RoHS Compliant(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-1(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-3(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-7(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-9(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-12(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-14(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-15(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-16(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-17(1)
-
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD), Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-31(1)
-
UL Recognized Component, ITE, E137632, UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition; CE Low Voltage Directive, IEC/EN 60950-1, 2nd Edition(1)
-
cULus Listed, Industrial Control Equipment, E61379, ITE, E137632, UL 508, CSA C22.2 No. 107.1, UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition, CE - Low Voltage Directive, IEC/EN60950-1, 2nd Edition(2)
-
UL Listed, Industrial Control Equipment for US and Canada: UL 508, CSA C22.2 No. 107.1; UL Recognized Component, ITE for US and Canada: UL 60950-1/CSA C22.2 60950-1 2nd edition; CE: IEC/EN 60950-1 2nd edition CB Scheme(2)
-
UL Listed, Industrial Control Equipment for US and Canada: UL 508, CSA C22.2 No. 107.1; UL Recognized Component, ITE for US and Canada: UL 60950-1/CSA C22.2 60950-1 2nd edition; CE: IEC/EN 60950-1 2nd edition CB Scheme, NEC Class 2(3)
-
UL Listed, Industrial Control Equipment for US and Canada: UL 508, CSA C22.2 No. 107.1; UL Recognized Component, ITE for US and Canada: UL 62368-1/CSA C22.2 No. 62368-1, UL 60950-1/CSA C22.2 No. 60950-1; CE: IEC/EN60950-1, IEC/EN62368-1; cCSAus ANSI/ISA-1(3)
-
UL Listed, Industrial Control Equipment for US and Canada: UL 508, CSA C22.2 No. 107.1; UL Recognized Component, ITE for US and Canada: UL 62368-1/CSA C22.2 No. 62368-1, UL 60950-1/CSA C22.2 No. 60950-1; CE: IEC/EN60950-1, IEC/EN62368-1(1)
-
UL, CE, Class 1 Zone 2, ATEX, IECEx(2)
Style
-
DIN Rail Mount(1)
Temperature Rating
-
115 DEG C Temperature Rise Under Full Load(2)
-
80 DEG Temperature Rise under full load(1)
-
150 DEG C Rise(1)
Type
-
SDN Series Redundant Options(2)
-
Automation Transformers - Non-Ventilated 50 VA to 45 kVA(1)
-
SDP Low Power DIN Rail Series(6)
-
SCP Series, 30 Watt; Dual(11)
-
SCP Series, 30 Watt; Single(6)
-
SCP Series, 30 Watt; Triple(1)
-
SDN-P DIN Rail Series(3)
-
Chassis Mount Bracket for SDN-P Series Power Supplies(1)
-
HSZ Series Industrial Control Transformers(1)
-
Silver Line Series - Single & Multi-Output Linears(28)
-
Linear OEM - Single Output Power Supply(3)
-
Power A/C Distribution (PAD)(1)
-
SDN-C Compact DIN Rail Series(4)
-
GL Series Single & Multi Output Switchers(11)
-
SHP Series: Heavy Duty Modular Power Supplies(1)
-
IP67 SCP-X Extreme Enviornment Series(2)
-
SVL Essential Din Rail Series(9)
-
SDN-D High Performance DIN Rail Series(2)
Voltage Rating
-
24 V(2)
-
12 V(2)
-
15 V(1)
-
5 V(2)
-
48 V(1)
-
35 V(2)
-
100, 120, 220, 230, 240 Selectable(2)
-
85 to 264V AC, 90 to 375V DC(5)
-
Dual O/P +/- 12 V V(2)
-
Dual O/P +/- 15 V V(2)
-
Dual O/P 5 V & 24 V V(2)
-
3.3 V(2)
-
Dual O/P 5 V & 12 V V(1)
-
Triple O/P 5/12/12 V V(1)
-
24 Vdc(2)
-
115/230 VAC(1)
-
N/A(5)
-
100, 120, 220, 230, 240 Selectable VAC(24)
-
104 to 127/208 to 254 VAC(3)
-
120 VAC(1)
-
85 to 132, 176 to 264V AC, 210 to 375V DC(1)
-
85-264 Vac/120-300 Vdc(8)
-
85-132 Vac or 170-264 Vac auto select, 220-300 Vdc(1)
-
85-264 Vac or 120-300 Vac(1)
-
Input Voltage 24 V(1)
-
AC Range 85 - 264 Vac Universal Input; DC Range 100-353 Vdc(2)
-
24(6)
-
5(1)
-
48(1)
-
12(1)
Wattage
-
240 W(2)
-
960 W(1)
-
480 W(2)
-
120 W(2)
-
1.5 KVA(1)
-
30 -100 WAT(1)
-
16.4 WAT(1)
-
N/A(7)
-
7.5 KVA(1)
-
25 to 500 Watts(1)
-
30 W(1)
-
15 W(1)
-
48 W(1)
Width
-
2.5 IN(4)
-
1.97 IN(2)
-
10 IN(1)
-
2.67 IN(1)
-
4.55(1)
-
1.62(1)
-
14 IN(1)
-
2.75 IN(7)
-
1.62 IN(3)
-
2.76 IN(3)
-
2.52 IN(1)
-
2.5(1)
-
4.28 IN(2)
-
4.25 IN(2)
-
5 IN(3)
-
3 IN(3)
-
7 in(1)
Winding
-
Aluminum Wound(1)
-
Copper(1)
Manufacturers
Products from this Category
Showing 165 results
-
SolaHD #:0/40RED
EXT.RED MOD 40A MAX 22.5-28.5V
Edwards #:SOLA0/40RED[Call For Price] -
SolaHD #:0S12B-DN
30W 12V SW PWWR SPLY SLIM DIN
Edwards #:SOLA0S12B-DN[Call For Price] -
SolaHD #:0S48B-DN
30W 48V SW PWR SPLY SLIM DIN
Edwards #:SOLA0S48B-DN[Call For Price] -
SolaHD #:0D15B-DN
30W 15/15V SW P S SLIM DIN
Edwards #:SOLA0D15B-DN[Call For Price] -
SolaHD #:0T515B-DN
30W 5/15/15V SW P S SLIM DIN
Edwards #:SOLA0T515B-DN[Call For Price] -
SolaHD #:00S24X-CP
100W 24V EXT.ENV. CONTROL DCPS
Edwards #:SOLA00S24X-CP[Call For Price]
Showing 165 results