Time relay
Time relay
Adjustable time / Full-scale value
-
100.00 h s(1)
Adjustable time / initial value
-
0.05 s(1)
Ambient temperature / during operation / maximum
-
60 C(1)
Ambient temperature / during operation / minimum
-
-25 C(1)
Ambient temperature / during storage / maximum
-
85 C(3)
Ambient temperature / during storage / minimum
-
-40 C(2)
Ambient temperature / during transport / maximum
-
85 C(2)
Ambient temperature / during transport / minimum
-
-40 C(2)
Ampacity / of the bridge terminals / maximum
-
10 A(1)
AWG number / as coded connectable conductor cross section / solid / maximum
-
12(1)
AWG number / as coded connectable conductor cross section / solid / minimum
-
20(1)
Category / acc. to EN 954-1
-
none(3)
Conducted interference / due to burst / acc. to IEC 61000-4-4
-
2kVnetworkconnection/1kVcontrolconnection(3)
Conducted interference / due to conductor-conductor surge / acc. to IEC 61000-4-5
-
1kV(3)
Conducted interference / due to conductor-earth surge / acc. to IEC 61000-4-5
-
2kV(3)
Contact Rating
-
R300 / B300(12)
-
B300 / R300(1)
Contact reliability / of auxiliary contacts
-
oneincorrectswitchingoperationof100millionswitchingoperations(17V,5mA)(1)
Control supply voltage / 1 / at AC / at 50 Hz / Final rated value
-
240 V(1)
Control supply voltage / 1 / at AC / at 50 Hz / Initial rated value
-
24 V(1)
-
12 V(1)
Control supply voltage / 1 / at AC / at 60 Hz / Initial rated value
-
12 V(1)
Control supply voltage frequency / 1 / Final rated value
-
60 Hz(1)
Degree of pollution
-
3(3)
Depth
-
74 mm(1)
-
90 mm(8)
Design of the fuse link / for short-circuit protection of the auxiliary switch / required
-
fusegL/gG:4A(3)
Design of the thread / of the connection screw
-
M3(2)
Electrical endurance (switching cycles) / at AC-15 / at 230 V / typical
-
100000(1)
Electrostatic discharge / acc. to IEC 61000-4-2
-
4kVcontactdischarge/8kVairdischarge(3)
Enclosure
-
IP20(13)
Environmental Conditions
-
85 -40 C(13)
-
80 -40 C(2)
Field-bound parasitic coupling / acc. to IEC 61000-4-3
-
10V/m(3)
Height
-
38 mm(1)
-
100 mm(8)
Influence of the surrounding temperature
-
1%inthewholetemperaturerangetothesetruntime(2)
Installation altitude / at height above sea level / maximum
-
2000 m(2)
Material / of switching contacts
-
AgSnO2(2)
Mechanical service life (switching cycles) / typical
-
10000000(1)
Mounting
-
screw and snap-on mounting onto 35 mm standard mounting rail any(13)
-
clip-on any (like contactor)(2)
mounting position
-
any(3)
Mounting type
-
screwandsnap-onmountingonto35mmstandardmountingrail(1)
Number of CO contacts / delayed switching
-
2(1)
Operating current / of auxiliary contacts / at DC-13 / at 125 V
-
0.2 A(1)
Operating current / of auxiliary contacts / at DC-13 / at 24 V
-
1 A(1)
Operating current / of auxiliary contacts / at DC-13 / at 250 V
-
0.1 A(1)
Operating Cycles
-
10M(14)
-
100000000(1)
Operating range factor control supply voltage rated value / at DC / Full-scale value
-
1.1(1)
Operating range factor control supply voltage rated value / at DC / initial value
-
0.85(1)
Operating Temperature
-
60.0 -25.0 C(9)
-
60.0 -25.0 C(2)
Power loss [V?A] / at AC / maximum
-
3.35 VA(1)
Power loss [W] / total / typical
-
2 W(1)
Power supply influence
-
1%inthewholevoltagerangetothesetruntime(2)
Product category
-
Furtheraccessories(1)
Product component / Relay output
-
Yes(1)
Product designation
-
Screwadapterforcontactors,sizeS0/S2(1)
-
timingrelay(2)
Product extension / optional / remote control
-
No(1)
Product extension / required / remote control
-
No(1)
Product function / at the relay outputs / Switchover delayed/without delay
-
No(1)
Protection against electrical shock
-
finger-safe(2)
Protection class IP
-
IP20(1)
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750
-
K(1)
Reference code / acc. to DIN EN 61346-2
-
K(1)
Reference code / acc. to DIN EN 81346-2
-
K(1)
Relative humidity / during operation / maximum
-
95 %(1)
Relative humidity / during operation / minimum
-
10 %(1)
Resistance
-
4000(4)
Surge voltage resistance / rated value
-
4000 V(1)
Switching capacity current / with inductive load / maximum
-
3 A(2)
Switching capacity current / with inductive load / minimum
-
0.01 A(1)
Switching function / flashing asymmetrically starting with pulse
-
No(2)
Switching function / ON-delay
-
Yes(2)
Switching function / passing make contact
-
No(2)
Switching function / passing make contact/instantaneous contact
-
No(1)
Switching function / with control signal / additive ON delay
-
No(2)
Switching function / with control signal / passing break contact
-
No(2)
Switching function / with control signal / pulse-shaping
-
No(1)
Test voltage / for isolation test
-
2.5 kV(2)
Thermal current
-
5 A(1)
Tightening torque / maximum
-
0.8 N.m(2)
Tightening torque / minimum
-
0.6 N.m(2)
Type
-
3RP20 Timing Relay(4)
-
3RP15 Timing Relay(9)
-
3RA Accessory(2)
Type of connectable conductor cross-sections / at AWG conductors / solid
-
1x(20...12),2x(20...14)(1)
Type of connectable conductor cross-sections / at AWG conductors / stranded
-
1x(20...12),2x(20...14)(1)
Type of connectable conductor cross-sections / finely stranded / with core end processing
-
1x(0.5...4mm),2x(0.5...1.5mm)(1)
Type of connectable conductor cross-sections / for auxiliary contacts / solid
-
2x(0.5...2.5mm),1x4mm(1)
Type of connectable conductor cross-sections / solid
-
1x(0.5...4.0mm),2x(0.5...2.5mm)(1)
Type of electrical connection / for auxiliary and control current circuit
-
screw-typeterminals(2)
Type of insulation
-
Basicinsulation(2)
Type of voltage / of the control supply voltage
-
AC/DC(3)
Vibration resistance / acc. to IEC 60068-2-6
-
10...55Hz/0.35mm(2)
Width
-
45 mm(1)
-
17.5 mm(4)
-
22.5 mm(4)
Manufacturers
Products from this Category
Showing 45 results
-
Siemens Industry #:3RP1540-1BB31
TIMING RELAY,OFF-DELAY,9TIME SETT.RANGES
Edwards #:SIEM3RP1540-1BB31[Call For Price]