Control relay

Adjustable response delay time / when starting / Full-scale value

  • 99 s
    (2)

Ambient temperature / during operation / maximum

  • 55 C
    (4)
  • 60 C
    (3)

Ambient temperature / during operation / minimum

  • -25 C
    (4)

Apparent holding power / of the magnet coil / at AC

  • 5.7 VA
    (1)

Arcing time / maximum

  • 15 ms
    (2)

Arcing time / minimum

  • 10 ms
    (1)

B10 value / with high demand rate / acc. to SN 31920

  • 1000000
    (1)

B10 value / with high demand rate / acc. to SN 31920 / Note

  • With0.3xIe
    (2)

Closing delay / at DC / maximum

  • 100 ms
    (1)

Closing delay / at DC / minimum

  • 30 ms
    (1)

Contact reliability / of auxiliary contacts

  • 1faultyswitchingper100million(17V,1mA)
    (1)

Control supply voltage frequency / 1 / rated value

  • 50 Hz
    (1)

Control supply voltage frequency / 2 / rated value

  • 60 Hz
    (1)

Degree of pollution

  • 3
    (8)

Depth

  • 68 mm
    (2)
  • 135 mm
    (5)
  • 102 mm
    (3)
  • 91 mm
    (3)
  • 117 mm
    (10)
  • 73 mm
    (26)
  • 121 mm
    (1)
  • 80 mm
    (4)
  • 92 mm
    (1)

Failure rate [FIT] / with low demand rate / acc. to SN 31920

  • 100 FIT
    (8)

Height

  • 48 mm
    (2)
  • 78 mm
    (8)
  • 87 mm
    (3)
  • 57.5 mm
    (28)
  • 70 mm
    (9)
  • 79 mm
    (2)
  • 90 mm
    (2)
  • 109 mm
    (1)

Identification number and letter for switching elements

  • 22E
    (1)
  • 40E
    (2)
  • 31E
    (1)
  • 44E
    (1)
  • 71E
    (1)

Installation altitude / at height above sea level / maximum

  • 2000 m
    (1)

Insulation voltage / with degree of pollution 3 / rated value

  • 690 V
    (2)

mounting position

  • +/-180rotationpossibleonverticalmountingsurface;canbetiltedforwardandbackwardby+/-22.5onverticalmountingsurface
    (4)

Mounting type

  • screwandsnap-onmountingonto35mmstandardmountingrail
    (6)
  • directmounting
    (1)
  • snap-onmounting
    (2)

No-load switching frequency / at DC

  • 10000 1/h
    (2)

Number of NC contacts / for auxiliary contacts

  • 1
    (2)
  • 2
    (3)
  • 3
    (1)

Number of NC contacts / for auxiliary contacts / instantaneous contact

  • 2
    (1)

Number of NO contacts / for auxiliary contacts

  • 3
    (1)
  • 7
    (1)
  • 4
    (1)

Number of NO contacts / for auxiliary contacts / instantaneous contact

  • 2
    (1)

Opening delay / at AC / maximum

  • 15 ms
    (2)

Opening delay / at AC / minimum

  • 4 ms
    (1)

Opening delay / at DC / minimum

  • 7 ms
    (1)

Operating current / at 1 current path / at DC-12 / at 220 V / rated value

  • 1 A
    (2)

Operating current / at 1 current path / at DC-12 / at 24 V / rated value

  • 10 A
    (1)

Operating current / at 1 current path / at DC-12 / at 440 V / rated value

  • 0.3 A
    (1)

Operating current / at 1 current path / at DC-12 / at 600 V / rated value

  • 0.15 A
    (1)

Operating current / at 1 current path / at DC-13 / at 110 V / rated value

  • 1 A
    (1)

Operating current / at 1 current path / at DC-13 / at 220 V / rated value

  • 0.3 A
    (1)

Operating current / at 1 current path / at DC-13 / at 24 V / rated value

  • 6 A
    (1)

Operating current / at 1 current path / at DC-13 / at 440 V / rated value

  • 0.14 A
    (2)

Operating current / at 1 current path / at DC-13 / at 600 V / rated value

  • 0.1 A
    (3)

Operating current / at AC-12 / maximum

  • 10 A
    (2)

Operating current / at AC-15 / at 230 V / rated value

  • 6 A
    (1)

Operating current / at AC-15 / at 400 V / rated value

  • 3 A
    (1)

Operating current / at AC-15 / at 500 V / rated value

  • 2 A
    (1)

Operating current / of auxiliary contacts / at DC-13 / at 24 V

  • 1 A
    (2)

Operating current / with 2 current paths in series / at DC-12 / at 110 V / rated value

  • 4 A
    (1)

Operating current / with 2 current paths in series / at DC-12 / at 220 V / rated value

  • 2 A
    (2)

Operating current / with 2 current paths in series / at DC-12 / at 60 V / rated value

  • 10 A
    (2)

Operating current / with 2 current paths in series / at DC-12 / at 600 V / rated value

  • 0.65 A
    (2)

Operating current / with 2 current paths in series / at DC-13 / at 220 V / rated value

  • 0.9 A
    (1)

Operating current / with 2 current paths in series / at DC-13 / at 24 V / rated value

  • 10 A
    (2)

Operating current / with 2 current paths in series / at DC-13 / at 440 V / rated value

  • 0.2 A
    (2)

Operating current / with 2 current paths in series / at DC-13 / at 60 V / rated value

  • 3.5 A
    (1)

Operating current / with 2 current paths in series / at DC-13 / at 600 V / rated value

  • 0.1 A
    (1)

Operating current / with 3 current paths in series / at DC-12 / at 110 V / rated value

  • 10 A
    (2)

Operating current / with 3 current paths in series / at DC-12 / at 220 V / rated value

  • 3.6 A
    (1)

Operating current / with 3 current paths in series / at DC-12 / at 60 V / rated value

  • 10 A
    (2)

Operating current / with 3 current paths in series / at DC-12 / at 600 V / rated value

  • 1.8 A
    (1)

Operating current / with 3 current paths in series / at DC-13 / at 110 V / rated value

  • 3 A
    (2)

Operating current / with 3 current paths in series / at DC-13 / at 220 V / rated value

  • 1.2 A
    (1)

Operating current / with 3 current paths in series / at DC-13 / at 24 V / rated value

  • 10 A
    (1)

Operating frequency / at AC-12 / maximum

  • 1000 1/h
    (1)

Operating frequency / at AC-15 / maximum

  • 1000 1/h
    (1)

Operating frequency / at DC-12 / maximum

  • 1000 1/h
    (1)

Operating frequency / at DC-13 / maximum

  • 1000 1/h
    (1)

Product designation

  • Monitoringrelays
    (1)

Product function / active current monitoring

  • Yes
    (2)

Product function / Current window recognition DC

  • No
    (1)

Product function / Overcurrent detection 1 phase

  • No
    (1)

Product function / Overcurrent detection DC

  • No
    (2)

Product function / Overcurrent monitoring

  • Yes
    (2)

Product function / positively driven operation acc. to IEC 60947-5-1

  • Yes
    (3)

Product function / positively driven operation acc. to IEC 60947-5-1 / Note

  • with3RH29
    (1)

Product function / removable terminal for main circuit

  • No
    (1)

Product function / Voltage window recognition 1 phase

  • No
    (1)

Product variations

  • &DHMK2_3RH2&,&DHMK1_3RH2&
    (1)

Proportion of dangerous failures / with high demand rate / acc. to SN 31920

  • 73 %
    (2)

Proportion of dangerous failures / with low demand rate / acc. to SN 31920

  • 40 %
    (3)

Protection against electrical shock

  • finger-safe
    (1)

Protection class IP

  • IP20
    (2)

Protection class IP / on the front

  • IP20
    (3)

Reference code / acc. to DIN EN 61346-2

  • K
    (3)

Reference code / acc. to DIN EN 81346-2

  • K
    (5)

Required spacing / for grounded parts / downwards

  • 10 mm
    (2)

Required spacing / for grounded parts / forwards

  • 10 mm
    (1)

Required spacing / for grounded parts / upwards

  • 6 mm
    (1)

Required spacing / for live parts / downwards

  • 10 mm
    (1)
  • 6 mm
    (1)

Required spacing / for live parts / forwards

  • 10 mm
    (1)
  • 0 mm
    (1)
  • 6 mm
    (2)

Required spacing / for live parts / upwards

  • 10 mm
    (2)

Required spacing / with side-by-side mounting / at the side

  • 0 mm
    (3)

Required spacing / with side-by-side mounting / downwards

  • 10 mm
    (2)

Required spacing / with side-by-side mounting / forwards

  • 10 mm
    (1)

Required spacing / with side-by-side mounting / upwards

  • 10 mm
    (1)

Shock resistance / at rectangular impulse / at DC

  • 10g/5ms,5g/10ms
    (2)

Shock resistance / with sine pulse / at DC

  • 15g/5ms,8g/10ms
    (2)

Short text (abstract) / with 80 characters / maximum

  • Monitoringrelay,canbemountedonto3RT2contactor,sizeS00standard,4-40A
    (1)

Size of contactor

  • S00
    (1)

Size of contactor / can be combined / company-specific

  • S00
    (1)

Surge voltage resistance / rated value

  • 6 kV
    (1)

T1 value / for proof test interval or service life / acc. to IEC 61508

  • 20 a
    (2)

Temperature drift per C

  • 0.1 %/C
    (1)

Type of connectable conductor cross-sections / at AWG conductors / for auxiliary contacts

  • 2x(20...16),2x(18...14),2x12
    (1)
  • 2x(20...14)
    (1)

Type of connectable conductor cross-sections / at AWG conductors / solid

  • 1x(20...14)
    (2)

Type of connectable conductor cross-sections / at AWG conductors / stranded

  • 1x(20...14)
    (1)

Type of connectable conductor cross-sections / finely stranded / with core end processing

  • 1x(0.25...1.5mm)
    (1)

Type of connectable conductor cross-sections / for auxiliary contacts / solid

  • 1x(0.5...4mm),2x(0.5...2.5mm)
    (1)

Type of connectable conductor cross-sections / solid

  • 1x(0.25...2.5mm)
    (2)

Type of current / for monitoring

  • AC
    (1)

Type of electrical connection / for auxiliary and control current circuit

  • spring-loadedterminals
    (1)
  • screw-typeterminals
    (1)
  • PUSH-INconnection(spring-loadedconnection)
    (1)

Type of switching contact

  • Changeovercontact
    (2)

Type of voltage

  • AC/DC
    (2)

Type of voltage / of the control supply voltage

  • DC
    (3)
  • AC
    (1)

Width

  • 45 mm
    (45)