Control relay
Control relay
Adjustable response delay time / when starting / Full-scale value
-
99 s(2)
Ambient temperature / during operation / maximum
-
55 C(4)
-
60 C(3)
Ambient temperature / during operation / minimum
-
-25 C(4)
Apparent holding power / of the magnet coil / at AC
-
5.7 VA(1)
Arcing time / maximum
-
15 ms(2)
Arcing time / minimum
-
10 ms(1)
B10 value / with high demand rate / acc. to SN 31920
-
1000000(1)
B10 value / with high demand rate / acc. to SN 31920 / Note
-
With0.3xIe(2)
Closing delay / at DC / maximum
-
100 ms(1)
Closing delay / at DC / minimum
-
30 ms(1)
Contact reliability / of auxiliary contacts
-
1faultyswitchingper100million(17V,1mA)(1)
Control supply voltage frequency / 1 / rated value
-
50 Hz(1)
Control supply voltage frequency / 2 / rated value
-
60 Hz(1)
Degree of pollution
-
3(8)
Depth
-
68 mm(2)
-
135 mm(5)
-
102 mm(3)
-
91 mm(3)
-
117 mm(10)
-
73 mm(26)
-
121 mm(1)
-
80 mm(4)
-
92 mm(1)
Failure rate [FIT] / with low demand rate / acc. to SN 31920
-
100 FIT(8)
Height
-
48 mm(2)
-
78 mm(8)
-
87 mm(3)
-
57.5 mm(28)
-
70 mm(9)
-
79 mm(2)
-
90 mm(2)
-
109 mm(1)
Identification number and letter for switching elements
-
22E(1)
-
40E(2)
-
31E(1)
-
44E(1)
-
71E(1)
Installation altitude / at height above sea level / maximum
-
2000 m(1)
Insulation voltage / with degree of pollution 3 / rated value
-
690 V(2)
mounting position
-
+/-180rotationpossibleonverticalmountingsurface;canbetiltedforwardandbackwardby+/-22.5onverticalmountingsurface(4)
Mounting type
-
screwandsnap-onmountingonto35mmstandardmountingrail(6)
-
directmounting(1)
-
snap-onmounting(2)
No-load switching frequency / at DC
-
10000 1/h(2)
Number of NC contacts / for auxiliary contacts
-
1(2)
-
2(3)
-
3(1)
Number of NC contacts / for auxiliary contacts / instantaneous contact
-
2(1)
Number of NO contacts / for auxiliary contacts
-
3(1)
-
7(1)
-
4(1)
Number of NO contacts / for auxiliary contacts / instantaneous contact
-
2(1)
Opening delay / at AC / maximum
-
15 ms(2)
Opening delay / at AC / minimum
-
4 ms(1)
Opening delay / at DC / minimum
-
7 ms(1)
Operating current / at 1 current path / at DC-12 / at 220 V / rated value
-
1 A(2)
Operating current / at 1 current path / at DC-12 / at 24 V / rated value
-
10 A(1)
Operating current / at 1 current path / at DC-12 / at 440 V / rated value
-
0.3 A(1)
Operating current / at 1 current path / at DC-12 / at 600 V / rated value
-
0.15 A(1)
Operating current / at 1 current path / at DC-13 / at 110 V / rated value
-
1 A(1)
Operating current / at 1 current path / at DC-13 / at 220 V / rated value
-
0.3 A(1)
Operating current / at 1 current path / at DC-13 / at 24 V / rated value
-
6 A(1)
Operating current / at 1 current path / at DC-13 / at 440 V / rated value
-
0.14 A(2)
Operating current / at 1 current path / at DC-13 / at 600 V / rated value
-
0.1 A(3)
Operating current / at AC-12 / maximum
-
10 A(2)
Operating current / at AC-15 / at 230 V / rated value
-
6 A(1)
Operating current / at AC-15 / at 400 V / rated value
-
3 A(1)
Operating current / at AC-15 / at 500 V / rated value
-
2 A(1)
Operating current / of auxiliary contacts / at DC-13 / at 24 V
-
1 A(2)
Operating current / with 2 current paths in series / at DC-12 / at 110 V / rated value
-
4 A(1)
Operating current / with 2 current paths in series / at DC-12 / at 220 V / rated value
-
2 A(2)
Operating current / with 2 current paths in series / at DC-12 / at 60 V / rated value
-
10 A(2)
Operating current / with 2 current paths in series / at DC-12 / at 600 V / rated value
-
0.65 A(2)
Operating current / with 2 current paths in series / at DC-13 / at 220 V / rated value
-
0.9 A(1)
Operating current / with 2 current paths in series / at DC-13 / at 24 V / rated value
-
10 A(2)
Operating current / with 2 current paths in series / at DC-13 / at 440 V / rated value
-
0.2 A(2)
Operating current / with 2 current paths in series / at DC-13 / at 60 V / rated value
-
3.5 A(1)
Operating current / with 2 current paths in series / at DC-13 / at 600 V / rated value
-
0.1 A(1)
Operating current / with 3 current paths in series / at DC-12 / at 110 V / rated value
-
10 A(2)
Operating current / with 3 current paths in series / at DC-12 / at 220 V / rated value
-
3.6 A(1)
Operating current / with 3 current paths in series / at DC-12 / at 60 V / rated value
-
10 A(2)
Operating current / with 3 current paths in series / at DC-12 / at 600 V / rated value
-
1.8 A(1)
Operating current / with 3 current paths in series / at DC-13 / at 110 V / rated value
-
3 A(2)
Operating current / with 3 current paths in series / at DC-13 / at 220 V / rated value
-
1.2 A(1)
Operating current / with 3 current paths in series / at DC-13 / at 24 V / rated value
-
10 A(1)
Operating frequency / at AC-12 / maximum
-
1000 1/h(1)
Operating frequency / at AC-15 / maximum
-
1000 1/h(1)
Operating frequency / at DC-12 / maximum
-
1000 1/h(1)
Operating frequency / at DC-13 / maximum
-
1000 1/h(1)
Product designation
-
Monitoringrelays(1)
Product function / active current monitoring
-
Yes(2)
Product function / Current window recognition DC
-
No(1)
Product function / Overcurrent detection 1 phase
-
No(1)
Product function / Overcurrent detection DC
-
No(2)
Product function / Overcurrent monitoring
-
Yes(2)
Product function / positively driven operation acc. to IEC 60947-5-1
-
Yes(3)
Product function / positively driven operation acc. to IEC 60947-5-1 / Note
-
with3RH29(1)
Product function / removable terminal for main circuit
-
No(1)
Product function / Voltage window recognition 1 phase
-
No(1)
Product variations
-
&DHMK2_3RH2&,&DHMK1_3RH2&(1)
Proportion of dangerous failures / with high demand rate / acc. to SN 31920
-
73 %(2)
Proportion of dangerous failures / with low demand rate / acc. to SN 31920
-
40 %(3)
Protection against electrical shock
-
finger-safe(1)
Protection class IP
-
IP20(2)
Protection class IP / on the front
-
IP20(3)
Reference code / acc. to DIN EN 61346-2
-
K(3)
Reference code / acc. to DIN EN 81346-2
-
K(5)
Required spacing / for grounded parts / downwards
-
10 mm(2)
Required spacing / for grounded parts / forwards
-
10 mm(1)
Required spacing / for grounded parts / upwards
-
6 mm(1)
Required spacing / for live parts / downwards
-
10 mm(1)
-
6 mm(1)
Required spacing / for live parts / forwards
-
10 mm(1)
-
0 mm(1)
-
6 mm(2)
Required spacing / for live parts / upwards
-
10 mm(2)
Required spacing / with side-by-side mounting / at the side
-
0 mm(3)
Required spacing / with side-by-side mounting / downwards
-
10 mm(2)
Required spacing / with side-by-side mounting / forwards
-
10 mm(1)
Required spacing / with side-by-side mounting / upwards
-
10 mm(1)
Shock resistance / at rectangular impulse / at DC
-
10g/5ms,5g/10ms(2)
Shock resistance / with sine pulse / at DC
-
15g/5ms,8g/10ms(2)
Short text (abstract) / with 80 characters / maximum
-
Monitoringrelay,canbemountedonto3RT2contactor,sizeS00standard,4-40A(1)
Size of contactor
-
S00(1)
Size of contactor / can be combined / company-specific
-
S00(1)
Surge voltage resistance / rated value
-
6 kV(1)
T1 value / for proof test interval or service life / acc. to IEC 61508
-
20 a(2)
Temperature drift per C
-
0.1 %/C(1)
Type of connectable conductor cross-sections / at AWG conductors / for auxiliary contacts
-
2x(20...16),2x(18...14),2x12(1)
-
2x(20...14)(1)
Type of connectable conductor cross-sections / at AWG conductors / solid
-
1x(20...14)(2)
Type of connectable conductor cross-sections / at AWG conductors / stranded
-
1x(20...14)(1)
Type of connectable conductor cross-sections / finely stranded / with core end processing
-
1x(0.25...1.5mm)(1)
Type of connectable conductor cross-sections / for auxiliary contacts / solid
-
1x(0.5...4mm),2x(0.5...2.5mm)(1)
Type of connectable conductor cross-sections / solid
-
1x(0.25...2.5mm)(2)
Type of current / for monitoring
-
AC(1)
Type of electrical connection / for auxiliary and control current circuit
-
spring-loadedterminals(1)
-
screw-typeterminals(1)
-
PUSH-INconnection(spring-loadedconnection)(1)
Type of switching contact
-
Changeovercontact(2)
Type of voltage
-
AC/DC(2)
Type of voltage / of the control supply voltage
-
DC(3)
-
AC(1)
Width
-
45 mm(45)