Motor starter controls
Motor starter controls
Adjustable OFF-delay time / after opening of the safety circuits / Full-scale value
-
30 s(1)
-
3 s(1)
Adjustable pick-up value current / 1 / Full-scale value
-
80 A(1)
Adjustable pick-up value current / 1 / initial value
-
8 A(1)
Adjustable pick-up value current / 2 / initial value
-
8 A(1)
Adjustable pick-up value current / of instantaneous short-circuit trip unit / maximum
-
100 A(1)
Adjustable pick-up value current / of overload relay / for low rotational speed / maximum
-
52 A(1)
Adjustable pick-up value current / of overload relay / for low rotational speed / minimum
-
13 A(1)
Adjustable switching hysteresis for measured current value / Full-scale value
-
16 A(2)
Adjustable switching hysteresis for measured current value / initial value
-
0.2 A(1)
Ambient temperature / during operation / maximum
-
60 C(37)
-
70 C(4)
-
40 C(11)
-
85 C(16)
-
50 C(1)
Ambient temperature / during operation / minimum
-
-25 C(18)
-
-20 C(21)
-
20 C(3)
-
0 C(5)
Ambient temperature / during operation / Note
-
Railwayapplication:-40...70?with10mmclearance.Seecatalogforotherratedconditions(2)
Ambient temperature / during storage / maximum
-
80 C(11)
-
90 C(11)
-
65 C(6)
-
70 C(1)
Ambient temperature / during storage / minimum
-
-55 C(9)
-
-40 C(12)
-
-30 C(3)
-
-50 C(3)
Ambient temperature / during transport / maximum
-
70 C(1)
Ambient temperature / during transport / minimum
-
-40 C(1)
Ambient temperature / rated value
-
60 C(1)
Ambient temperature [F] / during operation / maximum
-
140 F(5)
-
104 F(8)
Ambient temperature [F] / during operation / minimum
-
68 F(13)
-
-4 F(4)
Ambient temperature [F] / during storage / maximum
-
149 F(2)
-
176 F(9)
Ambient temperature [F] / during storage / minimum
-
-22 F(7)
-
122 F(11)
Ampacity / for overcurrent duration < 1 s / maximum permissible
-
1600 A(2)
Ampacity / for permanent overcurrent / maximum permissible
-
80 A(2)
Apparent holding power / of the magnet coil / at AC
-
25.0 VA(7)
-
25 VA(1)
-
25.00 VA(1)
-
5.7 VA(3)
-
8.5 VA(1)
Apparent pick-up power / of the magnet coil / at AC
-
510 VA(1)
-
37.0 VA(3)
-
218 VA(1)
Application area
-
forswitchingthecontrolsignalsinthecontrolcircuit(5)
-
forswitchingthecontrolsignalsinthecontrolcircuitwithoptionofdirectconnectiontoelectroniccontrollers(2)
-
fortheexpansionofauxiliarycontactsinthecontrolcircuit(1)
Arcing time / maximum
-
15 ms(4)
Arcing time / minimum
-
10 ms(11)
Auxiliary contacts in total / maximal
-
8(4)
AWG number / as coded connectable conductor cross section / for main contacts / minimum
-
18(1)
AWG number / as coded connectable conductor cross section / solid / maximum
-
14(1)
-
16(1)
B10 value / with high demand rate / acc. to SN 31920
-
1000000(9)
B10 value / with high demand rate / acc. to SN 31920 / Note
-
With0.3xIe(7)
Backslide delay time / after opening of the safety circuits / typical
-
40 ms(2)
Cable entry type
-
1x(M20x1.5)(8)
-
3x(M20x1.5)(2)
Certificate of suitability
-
UL(9)
-
NEMAICS2;UL508;CSA22.2,No.14(9)
-
NEMAICS2;UL508A(4)
-
CE/UL/CSA/CCC(22)
Certificate of suitability / ATEX
-
Yes(6)
Circuit principle
-
reedswitches(1)
Circuit principle / of the output relay
-
closed-circuitcurrent/open-circuitcurrent(1)
Closing delay / at AC / maximum
-
33 ms(1)
Closing delay / at AC / minimum
-
8 ms(5)
Closing delay / at DC / maximum
-
100 ms(2)
Closing delay / at DC / minimum
-
30 ms(2)
Closing power / of magnet coil / at DC
-
4 W(3)
-
2.8 W(2)
-
13 W(1)
Color
-
turquoise(1)
Color / of accessory
-
sandgray(1)
Color / of the actuating element
-
red/yellow(1)
-
black(1)
Conducted HF-interference emissions / acc. to CISPR11
-
ClassBfordomestic,businessandcommercialenvironments;ClassAforindustrialenvironmentsat110VDC(23)
-
ClassBforthedomestic,businessandcommercialenvironments(20)
Conducted interference / due to burst / acc. to IEC 61000-4-4
-
3kV/5kHz(51)
Conducted interference / due to conductor-conductor surge / acc. to IEC 61000-4-5
-
1kV(13)
-
2kV(36)
Conducted interference / due to conductor-earth surge / acc. to IEC 61000-4-5
-
2kV(10)
-
4kVsignallines2kV(36)
Conducted interference / due to high-frequency radiation / acc. to IEC 61000-4-6
-
10V(43)
Configuration of control input / 4
-
NA(2)
-
FactorysetasTRIPRESET(2)
Connectable conductor cross-section / for main contacts / stranded / maximum
-
50 mm2(1)
Connectable conductor cross-section / for main contacts / stranded / minimum
-
1 mm2(1)
Connectable conductor cross-section / solid / maximum
-
2.5 m mm2(1)
-
1.5 m mm2(1)
Connection
-
insulationpiercingmethodforAS-Interfaceflatcable(1)
-
usingremovablescrew-typeterminalstoAS-i,PC/RS232using9-poleD-Subconnector(1)
Contact rating / of auxiliary contacts / according to UL
-
A600/Q600(6)
-
B300/R300(1)
Contact rating / of the auxiliary contacts / of the overload relay / acc. to UL
-
10A@600VAC(A600),5A@250VDC(P300)(1)
-
5A@600VAC(B600),5A@250VDC(P300)(1)
-
5A@600VAC(B600),1A@250VDC(R300)(2)
Contact rating / of the auxiliary contacts / of the contactor / acc, to UL
-
10A@600VAC(A600),5A@600VDC(P600)(5)
Contact reliability / of auxiliary contacts
-
1faultyswitchingper100million(17V,1mA)(10)
Continuous current / of the C characteristic MCB
-
1 A(12)
Continuous current / of the DIAZED fuse link gG
-
6 A(9)
-
4 A(1)
Continuous current / of the quick DIAZED fuse link
-
10 A(6)
-
4 A(1)
Control supply voltage / 1 / at AC / at 50 Hz / Final rated value
-
600 V(1)
-
127 V(2)
-
400 V(1)
Control supply voltage / 1 / at AC / at 50 Hz / Initial rated value
-
127 V(1)
-
400 V(1)
-
48 V(1)
Control supply voltage / 1 / at AC / at 50 Hz / rated value
-
24 V(3)
-
400 V(2)
-
575 V(2)
-
690 V(2)
Control supply voltage / 1 / at AC / at 60 Hz / Final rated value
-
400 V(2)
-
240 V(1)
Control supply voltage / 1 / at AC / at 60 Hz / Initial rated value
-
400 V(1)
Control supply voltage / 1 / at DC / Final rated value
-
150 V(2)
-
70 V(1)
Control supply voltage / 1 / at DC / Initial rated value
-
70 V(2)
-
150 V(1)
-
24 V(1)
Control supply voltage / 1 / at DC / rated value
-
24 V(10)
Control supply voltage / at AC / at 50 Hz / rated value
-
220 V(1)
Control supply voltage / at AC / at 50 Hz / Rated value / maximum
-
0 V(4)
-
690.0 V(1)
Control supply voltage / at AC / at 50 Hz / Rated value / minimum
-
23 V(1)
-
420.0 V(1)
-
320.0 V(1)
-
160.0 V(1)
-
110 V(2)
-
380 V(1)
Control supply voltage / at AC / at 60 Hz / rated value
-
120V(2)
-
120 V(1)
-
24.0 V(1)
-
277 V(1)
Control supply voltage / at AC / at 60 Hz / Rated value / maximum
-
240 V(3)
Control supply voltage / at AC / at 60 Hz / Rated value / minimum
-
160.0 V(1)
-
220 V(1)
-
120 V(1)
-
110 V(2)
-
440 V(1)
-
100 V(1)
Control supply voltage / at DC / rated value
-
110 V(2)
-
250 V(1)
Control supply voltage / at DC / Rated value / maximum
-
0 V(6)
-
28.8 V(1)
Control supply voltage / at DC / Rated value / minimum
-
220 V(1)
-
23 V(1)
-
0 V(1)
-
21.6 V(1)
Control supply voltage frequency / 1 / rated value
-
50 Hz(8)
Control supply voltage frequency / 2 / rated value
-
60 Hz(11)
country of origin
-
Mexico(1)
-
USA(3)
Current / at input / maximum
-
820 A(1)
Degree of pollution
-
3(104)
Degree of protection NEMA rating
-
NEMAType1(3)
-
NEMAType4(2)
-
1(1)
Degree of protection NEMA rating / of the enclosure
-
Opendevice(noenclosure)(1)
-
NEMAType1(1)
-
NEMA4,12(1)
Depth
-
85 mm(1)
-
64 mm(1)
-
84 mm(1)
-
31 mm(1)
-
89 mm(2)
-
108 mm(1)
-
10 mm(1)
-
73 mm(6)
-
117 mm(2)
-
121 mm(2)
-
58 mm(1)
-
121.6 mm(1)
Depth [in]
-
6 in(1)
-
5 in(2)
-
8 in(3)
Design of fuse holder
-
ClassRfuseclips(1)
Design of overload relay
-
SolidState(3)
Design of short-circuit protection
-
fuse(7)
-
circuit-breakers(5)
Design of the fuse link / for short-circuit protection of the auxiliary switch / required
-
fusegL/gG:10A(12)
Design of the fuse link / for short-circuit protection of the main circuit / required
-
10kA@600V(ClassHorK);100kA@600V(ClassRorJ)(3)
Design of the housing
-
Indoorgeneralpurposeuse(3)
Design of the housing / acc. to standard
-
Yes(3)
-
No(3)
Design of the product
-
ManualStarter(4)
-
ManualSwitch(3)
-
K45mountingplateforwallmounting(1)
-
Sidemoduletowidenmountingrailadapters(1)
-
scalecover,sealable,forcoveringthecurrentsettingscale(1)
-
Assembly(4)
-
Installation(1)
-
Non-reversingmotorstarter(3)
-
Reversingmotorstarter(1)
-
Full-voltagenon-reversingmotorstarter(7)
-
Non-reversingmotorstarterwithfusibledisconnect(5)
-
Full-voltagenon-reversingmotorstarterwithnon-fusibledisconnect(1)
-
Non-reversingmotorstarterwithnon-fusibledisconnect(1)
-
OFFdelaydevice(2)
-
offdelay(1)
-
with2auxiliarycontacts(1)
-
standard(1)
-
Forsimpleprotectionagainstunauthorizedaccess(1)
-
Forheightadjustmentfordeviceswithoutelectricalconnectionviadeviceconnector,withawidthof22.5mmorgreater(1)
-
For3SK1213/width>45mm(1)
-
For3SK1/width17.5mm(1)
-
For3SK1/width22.5mm(2)
-
Formechanicalcodingoftheterminals(1)
-
forsnappingontothefront,withSUVAapproval(1)
-
forreversingstartersizeS2,canbemountedlaterally(1)
-
fromabove,sizeS2(1)
-
fromabove,TypeE,sizeS2(1)
-
visibleisolatingdistance,canbelockedindisengagedposition(1)
-
actuatingvoltagecontactor:ACandDC(2)
-
TypeEacc.toUL(1)
-
for30.5mmto22.5mmmountinghole(1)
-
forsnappingontothefront(1)
Design of the product / Standard position switch
-
Yes(2)
Design of the product / with separate actuator
-
No(1)
Design of the product / with tumbler
-
No(2)
Design of the short-circuit trip
-
magnetic(2)
-
Thermalmagneticcircuitbreaker(3)
Design of the surge suppressor
-
withRCelements(4)
-
withvaristor(7)
-
withdiodeassemblies(1)
-
withsuppressordiode(1)
-
RCelement(5)
-
Diodecombination(2)
-
VaristorwithLED(3)
-
withdiode(1)
-
Varistor(1)
Diameter
-
38 mm(1)
Display version / LED
-
Yes(2)
Electrical endurance (switching cycles) / at AC-15 / at 230 V / typical
-
100000(1)
Electrical input frequency / maximum
-
60 Hz(2)
Electrostatic discharge / acc. to IEC 61000-4-2
-
4kVcontactdischarge/8kVairdischarge(11)
-
6kVcontactdischarge/8kVairdischarge(36)
EMC emitted interference / acc. to IEC 60947-1
-
ambienceA(industrialsector)(1)
EMI immunity / acc. to IEC 60947-1
-
ambienceA(industrialsector)(1)
Enclosure
-
NEMA 4(2)
Explosion protection marking / for intrinsic safety of related equipment / EEx ia
-
No(1)
Failure rate [FIT] / with low demand rate / acc. to SN 31920
-
100 FIT(100)
Field-bound HF-interference emission / acc. to CISPR11
-
ClassBforthedomestic,businessandcommercialenvironments(27)
-
ClassBfordomestic,businessandcommercialenvironments;ClassAforindustrialenvironmentsat110VDC(25)
Galvanic isolation / between entrance and outlet
-
Yes(2)
Galvanic isolation / between the outputs
-
Yes(2)
Galvanic isolation / between the voltage supply and other circuits
-
Yes(2)
Hardware fault tolerance / acc. to IEC 61508
-
1(1)
Height
-
36.5 mm(1)
-
36 mm(1)
-
155 mm(1)
-
107 mm(1)
-
175 mm(1)
-
170 mm(1)
-
57.5 mm(6)
-
70 mm(4)
-
46 mm(4)
-
19 mm(1)
-
265 mm(1)
-
73 mm(1)
-
100 mm(1)
-
30 mm(15)
-
40 mm(1)
Height of the sensor
-
13 mm(1)
Height [in]
-
24 in(1)
-
12.92 in(1)
-
7.69 in(1)
-
11 in(2)
-
15 in(1)
-
20 in(1)
Holding power / at AC / minimum
-
14 W(1)
-
8.6 W(1)
Holding power / of magnet coil / at DC
-
1.6 W(1)
-
2.8 W(1)
-
4 W(3)
Identification number and letter for switching elements
-
22E(21)
-
21(1)
-
31E(20)
-
40E(16)
-
44E(4)
-
62E(5)
Inductive power factor / with closing power of the coil
-
0.8(3)
Inductive power factor / with the holding power of the coil
-
0.25(2)
Input current / _2 / rated value
-
1.6 A(1)
Input current / _6 / rated value
-
3.9 A(1)
Installation altitude / at height above sea level / maximum
-
2000 m(12)
Installation altitude [ft] / at height above sea level / maximum
-
6560 ft(4)
Installation environment regarding EMC
-
ThisproductissuitableforClassBenvironmentsandcanalsobeusedindomesticenvironments.(1)
Insulation voltage / rated value
-
500 V(2)
-
300 V(2)
Insulation voltage / with degree of pollution 3 / rated value
-
690 V(7)
Insulation voltage / with multi-phase operation / at AC / Rated value
-
300 V(3)
Insulation voltage / with single-phase operation / at AC / Rated value
-
600 V(2)
Length of the sensor
-
33 mm(1)
Make time / with automatic start / after power failure / maximum
-
3 s(1)
Make time / with automatic start / at DC / maximum
-
110 ms(1)
-
85 ms(1)
Material
-
plastic(1)
Material / of accessory
-
Metalmatt(1)
Material / of the conductor / at overload relay / for auxiliary contacts
-
CU(9)
Material / of the conductor / for auxiliary contacts / of the contactor
-
CU(9)
Material / of the conductor / for load-side outgoing feeder
-
ALorCU(3)
-
CU(2)
Material / of the conductor / for supply
-
ALorCU(2)
Material / of the conductor / of the magnet coil
-
CU(7)
Material / of the enclosure
-
plastic(5)
-
aluminum(1)
Maximum short-circuit current breaking capacity (Icu) / at 400 V / rated value
-
100 k kA(5)
Measurable current / at AC / Full-scale value
-
80 A(1)
Measurable current / at AC / initial value
-
8 A(1)
Measurable voltage / at AC / Full-scale value
-
690 V(2)
Mechanical service life (switching cycles) / of contactor / typical
-
30000000(4)
-
10000000(1)
-
5000000(2)
Mechanical service life (switching cycles) / of the main contacts / typical
-
10000000(4)
-
5000000(2)
Mechanical service life (switching cycles) / typical
-
10000000(2)
Mounting
-
Flush(4)
Mounting height
-
4.6 mm(1)
mounting position
-
any(35)
-
vertical(2)
-
+/-180rotationpossibleonverticalmountingsurface;canbetiltedforwardandbackwardby+/-22.5onverticalmountingsurface(41)
Mounting type
-
clip-on(27)
-
wallmounting(8)
-
plug-infixing(1)
-
Surfacemountingandinstallation(2)
-
screws(1)
-
screwandsnap-onmountingonto35mmstandardmountingrail(67)
-
screwfixing(4)
-
directmounting(2)
-
snap-onmounting(1)
No-load switching frequency / at AC
-
10000 1/h(4)
No-load switching frequency / at DC
-
10000 1/h(7)
Number of CO contacts / for auxiliary contacts
-
1(1)
Number of interfaces / other
-
1(1)
Number of NC contacts / for auxiliary contacts
-
1(3)
-
2(1)
Number of NC contacts / for auxiliary contacts / instantaneous contact
-
2(4)
-
1(3)
Number of NC contacts / for auxiliary contacts / of the overload relay
-
1(4)
Number of NO contacts / at contactor / for auxiliary contacts
-
1(5)
Number of NO contacts / for auxiliary contacts
-
9(1)
-
1(14)
-
2(3)
-
3(2)
-
4(1)
Number of NO contacts / for auxiliary contacts / instantaneous contact
-
2(3)
-
3(3)
-
4(2)
Number of NO contacts / for auxiliary contacts / of the overload relay
-
1(1)
Number of NO contacts / for main contacts
-
3(5)
Number Of Poles
-
3(104)
-
1(2)
-
2(6)
Number of poles / for main current circuit
-
3(19)
-
2(2)
OFF-delay time / maximum
-
12 ms(1)
-
24 ms(7)
OFF-delay time / minimum
-
14 ms(1)
-
10 ms(2)
Opening delay / at AC / maximum
-
15 ms(4)
Opening delay / at AC / minimum
-
4 ms(5)
Opening delay / at DC / maximum
-
13 ms(3)
Opening delay / at DC / minimum
-
7 ms(3)
Operating class of the fuse link
-
ClassR(2)
Operating current / at 1 current path / at DC-12 / at 110 V / rated value
-
3 A(6)
Operating current / at 1 current path / at DC-12 / at 220 V / rated value
-
1 A(4)
Operating current / at 1 current path / at DC-12 / at 24 V / rated value
-
10 A(3)
Operating current / at 1 current path / at DC-12 / at 440 V / rated value
-
0.3 A(5)
Operating current / at 1 current path / at DC-12 / at 600 V / rated value
-
0.15 A(7)
Operating current / at 1 current path / at DC-13 / at 110 V / rated value
-
1 A(5)
Operating current / at 1 current path / at DC-13 / at 220 V / rated value
-
0.3 A(6)
Operating current / at 1 current path / at DC-13 / at 24 V / rated value
-
10 A(2)
-
6 A(2)
Operating current / at 1 current path / at DC-13 / at 440 V / rated value
-
0.14 A(4)
Operating current / at 1 current path / at DC-13 / at 600 V / rated value
-
0.1 A(8)
Operating current / at 17 V / minimum
-
5 mA(2)
Operating current / at AC / at 400 V / rated value
-
12 A(1)
-
32 A(2)
-
0.4 A(1)
-
4 A(2)
Operating current / at AC / at 600 V / rated value
-
270 A(1)
-
18 A(8)
-
27 A(2)
-
9 A(1)
Operating current / at AC-12 / maximum
-
10 A(5)
Operating current / at AC-15 / at 230 V / rated value
-
10 A(9)
Operating current / at AC-15 / at 400 V / rated value
-
3 A(4)
Operating current / at AC-15 / at 500 V / rated value
-
2 A(4)
Operating current / at AC-15 / at 690 V / rated value
-
1 A(5)
Operating current / at AC-3 / at 400 V / Rated value
-
2.50 A(1)
-
8.00 A(1)
-
20.00 A(1)
-
3.20 A(1)
-
16.00 A(1)
-
0.40 A(1)
Operating current / at DC-13 / at 24 V / rated value
-
3 A(1)
Operating current / of motor circuit breaker / rated value
-
10 A(1)
Operating current / of the auxiliary contacts / of the overload relay / at AC / at 600 V
-
5:00M A(2)
Operating current / of the auxiliary contacts / of the overload relay / at DC / at 250 V
-
1:00M A(4)
Operating current / rated value
-
108 A(1)
-
63 A(3)
Operating current / with 2 current paths in series / at DC-12 / at 110 V / rated value
-
4 A(7)
Operating current / with 2 current paths in series / at DC-12 / at 220 V / rated value
-
2 A(5)
Operating current / with 2 current paths in series / at DC-12 / at 24 V / rated value
-
10 A(5)
Operating current / with 2 current paths in series / at DC-12 / at 440 V / rated value
-
1.3 A(6)
Operating current / with 2 current paths in series / at DC-12 / at 60 V / rated value
-
10 A(8)
Operating current / with 2 current paths in series / at DC-12 / at 600 V / rated value
-
0.65 A(7)
Operating current / with 2 current paths in series / at DC-13 / at 110 V / rated value
-
1.3 A(10)
Operating current / with 2 current paths in series / at DC-13 / at 220 V / rated value
-
0.9 A(5)
Operating current / with 2 current paths in series / at DC-13 / at 24 V / rated value
-
10 A(3)
Operating current / with 2 current paths in series / at DC-13 / at 440 V / rated value
-
0.2 A(4)
Operating current / with 2 current paths in series / at DC-13 / at 60 V / rated value
-
3.5 A(7)
Operating current / with 2 current paths in series / at DC-13 / at 600 V / rated value
-
0.1 A(5)
Operating current / with 3 current paths in series / at DC-12 / at 110 V / rated value
-
10 A(5)
Operating current / with 3 current paths in series / at DC-12 / at 220 V / rated value
-
3.6 A(6)
Operating current / with 3 current paths in series / at DC-12 / at 24 V / rated value
-
10 A(8)
Operating current / with 3 current paths in series / at DC-12 / at 440 V / rated value
-
2.5 A(7)
Operating current / with 3 current paths in series / at DC-12 / at 60 V / rated value
-
10 A(3)
Operating current / with 3 current paths in series / at DC-12 / at 600 V / rated value
-
1.8 A(3)
Operating current / with 3 current paths in series / at DC-13 / at 110 V / rated value
-
3 A(2)
Operating current / with 3 current paths in series / at DC-13 / at 220 V / rated value
-
1.2 A(6)
Operating current / with 3 current paths in series / at DC-13 / at 24 V / rated value
-
10 A(6)
Operating current / with 3 current paths in series / at DC-13 / at 440 V / rated value
-
0.5 A(6)
Operating current / with 3 current paths in series / at DC-13 / at 60 V / rated value
-
4.7 A(8)
Operating current / with 3 current paths in series / at DC-13 / at 600 V / rated value
-
0.26 A(7)
Operating frequency / 2 / rated value
-
60 Hz(1)
Operating frequency / at AC-12 / maximum
-
1000 1/h(9)
Operating frequency / at AC-14 / maximum
-
1000 1/h(5)
Operating frequency / at AC-15 / maximum
-
1000 1/h(4)
Operating frequency / at DC-12 / maximum
-
1000 1/h(5)
Operating frequency / at DC-13 / maximum
-
1000 1/h(5)
Operating frequency / rated value / minimum
-
50 Hz(8)
Operating power / at AC-3 / at 230 V / rated value
-
1500 W(2)
-
4000 W(1)
-
550 W(1)
Operating power / at AC-3 / at 400 V / rated value
-
0.37 k kW(1)
-
1500 kW(4)
-
5.50 k kW(3)
-
15.00 k kW(1)
-
1.50 k kW(1)
-
7.50 k kW(1)
Operating power / for three-phase motors / at 400 V / at 50 Hz / maximum
-
0.37 kW(1)
-
1.1 kW(1)
Operating power / for three-phase motors / at 400 V / at 50 Hz / minimum
-
5.5 kW(1)
Operating voltage / at AC-3 / Rated value / maximum
-
600 V(13)
-
277 V(5)
-
575 V(2)
-
690 V(1)
Operating voltage / for main current circuit / at AC / at 60 Hz / maximum
-
600 V(3)
Operating voltage / rated value / maximum
-
400 V(1)
Phase number
-
3(1)
Power loss [V?A] / maximum
-
25 VA(1)
Power loss [W]
-
2.1 W(1)
Power Supply
-
208/230/460/575vac(12)
Product category
-
Terminalcovers(1)
-
Furtheraccessories(1)
-
Auxiliaryswitchblocks(1)
-
Baseplates(1)
Product component / Auxiliary switch
-
No(2)
-
Yes(1)
Product component / bottom wiring module
-
Yes(2)
Product component / top wiring module
-
Yes(2)
Product component / transparent cover
-
No(5)
Product component / Trip indicator
-
Yes(2)
Product designation
-
Non-reversingmotorstarter(13)
-
undervoltagerelease(18)
-
mechanicallatch(1)
-
ManualStarter(3)
-
ManualSwitch(3)
-
covercapsfortransverseauxiliaryswitch(1)
-
Identificationlabels(2)
-
shuntrelease(10)
-
signalingswitch(2)
-
individualmount(1)
-
surgesuppressor(28)
-
Cover(4)
-
Magnetcoil(1)
-
Terminalblock(2)
-
ISOsurface-mountedhousingwithEMERGENGYOFF(2)
-
ISOsurface-mountedhousing(1)
-
ISOinstallationhousingwithEMERGENCYOFF(1)
-
Alusurface-mountedhousingwithEMERGENCYOFF(1)
-
Boxterminalblock(3)
-
Coversforcablelugandbusbarconnections(1)
-
LEDdisplaymodule(1)
-
Coversforscrewterminals(1)
-
connectingcable(1)
-
auxiliaryswitch,lateral(1)
-
Reversingmotorstarter(2)
-
Lever-typerotaryoperatingmechanism(3)
-
Non-reversingmotorstarterwithfusibledisconnect(3)
-
Non-reversingmotorstarterwithnon-fusibledisconnect(1)
-
Auxiliarycontactor(10)
-
mountingrailadapter(1)
-
plug-inadditionalloadmodule(1)
-
openingdelaydeviceforcontactor(1)
-
Insulationstop(1)
-
pneumaticdelayblock(2)
-
Coilconnectionmodule(1)
-
Expansionplug(1)
-
disconnectormodule(2)
-
Cover,sealable(1)
-
Outgoingconnectorforcontactors,sizeS00/S0(1)
-
Adapterforcontactor,sizeS0(1)
-
Adapterforcontactor,sizeS00(1)
-
auxiliaryswitch(4)
-
door-couplingrotaryoperatingmechanism(1)
-
controlkit(1)
-
Couplingrelayforswitchingauxiliarycircuits(2)
-
Motorizedoperatingmechanism(2)
-
Deviceconnector(3)
-
Deviceterminationconnectorset(1)
-
Deviceterminationconnector(1)
-
Codingpinsforremovableterminals(1)
-
Outputexpansion(1)
-
Baseplate(1)
-
Mechanicallockingdevice(1)
-
Three-phasefeederterminal(2)
-
Contactorrelayforrailwayapplications(1)
-
Wiringkit(2)
-
Adapter(1)
Product extension / Auxiliary switch
-
No(3)
-
Yes(5)
Product feature / Protective coating on printed-circuit board
-
Yes(5)
Product function
-
Reversingmotorstarter(1)
-
solid-staterelay/solid-statecontactor3RF2(1)
-
Non-reversingmotorstarterwithfusibledisconnect(2)
-
Codingpinsforterminals(1)
-
Non-reversingmotorstarter(1)
Product function / active current monitoring
-
Yes(2)
Product function / Apparent current monitoring
-
Yes(1)
Product function / Auto-reset
-
Yes(1)
-
No(1)
Product function / Bus communication
-
No(23)
Product function / can be activated or deactivated / phase sequence recognition
-
Yes(1)
Product function / Control circuit interface to parallel wiring
-
No(1)
Product function / Current asymmetry detection acc. to IEC/NEMA
-
No(1)
Product function / Current asymmetry detection acc. to Siemens
-
No(1)
Product function / Current window recognition DC
-
No(3)
Product function / Disconnector functionality
-
Yes(6)
-
No(5)
Product function / dynamic wire break detection
-
No(1)
-
Yes(1)
Product function / EMERGENCY OFF function
-
No(5)
-
Yes(5)
Product function / External reset
-
Yes(5)
-
No(2)
Product function / Fault storage
-
No(2)
Product function / Galvanic isolation
-
Yes(2)
Product function / Ground fault detection
-
Yes(3)
Product function / Main switches with supply disconnect function and EM-STOP switches
-
No(1)
Product function / Manual RESET
-
No(1)
-
Yes(1)
Product function / motor protection
-
Yes(4)
Product function / Overcurrent and undercurrent monitoring
-
Yes(1)
Product function / Overcurrent detection 1 phase
-
No(1)
Product function / Overcurrent detection 3 phase
-
Yes(2)
Product function / Overcurrent detection DC
-
No(2)
Product function / Overcurrent monitoring
-
Yes(2)
Product function / overload protection
-
Yes(5)
Product function / Phase failure detection
-
Yes(7)
Product function / Phase unbalance
-
Yes(2)
Product function / positive opening
-
Yes(1)
Product function / positively driven operation acc. to IEC 60947-5-1
-
Yes(4)
Product function / positively driven operation acc. to IEC 60947-5-1 / Note
-
with3RH29(2)
Product function / removable terminal for auxiliary and control circuit
-
Yes(2)
Product function / reverse starting
-
No(1)
Product function / Short circuit protection
-
No(12)
-
Yes(7)
Product function / Switching cycle counter
-
No(1)
Product function / Test function
-
Yes(7)
Product function / undercurrent detection 1 phase
-
No(1)
Product function / undercurrent detection 3 phases
-
Yes(2)
Product function / undercurrent detection DC
-
No(1)
Product function / Undercurrent monitoring
-
Yes(1)
Product function / Voltage window recognition 1 phase
-
No(1)
Product function / Voltage window recognition 3 phase
-
No(1)
Product type designation
-
3RH2(9)
-
3RH19(1)
Product type designation / of soft starter
-
3RW403.,3RW404.(1)
Product variations
-
&DHMK2_3RH2&,&DHMK1_3RH2&(5)
Proportion of dangerous failures / with high demand rate / acc. to SN 31920
-
73 %(3)
Proportion of dangerous failures / with low demand rate / acc. to SN 31920
-
40 %(6)
Protection against electrical shock
-
(NAforenclosedproducts)(3)
-
NAforenclosedproducts(1)
-
finger-safe(12)
-
finger-safewhentouchedverticallyfromfrontacc.toIEC60529(2)
Protection class IP
-
IP20(47)
-
IP66,IP67,IP69(IP69K)(1)
Protection class IP / of the enclosure
-
IP55(7)
-
IP65(2)
-
IP20(1)
Protection class IP / on the front
-
IP20(31)
-
IP64(1)
Protocol / is supported / IO-Link protocol
-
No(1)
Protocol / is supported / PROFIBUS protocol
-
No(1)
Protocol / is supported / PROFIsafe protocol
-
No(1)
Pulse duration / of the ON pushbutton input / minimum
-
0.15 s(2)
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750
-
F(22)
-
K(13)
Reference code / acc. to DIN EN 61346-2
-
F(10)
-
K(9)
Reference code / acc. to DIN EN 81346-2
-
K(11)
Relative humidity / at 25 C / during operation / maximum
-
95 %(1)
Relative humidity / during operation / maximum
-
95 %(1)
Relative humidity / during operation / minimum
-
10 %(1)
Relative repeat accuracy
-
1 %(4)
Release voltage in percent / of the magnet coil / relating to input voltage
-
60 %(1)
-
50 %(6)
-
50.00 %(1)
Required spacing / for grounded parts / at the side
-
6 mm(7)
Required spacing / for grounded parts / downwards
-
10 mm(7)
Required spacing / for grounded parts / forwards
-
10 mm(11)
Required spacing / for grounded parts / upwards
-
10 mm(7)
-
50 mm(1)
Required spacing / for live parts / at the side
-
6 mm(5)
Required spacing / for live parts / Backwards
-
0 mm(1)
Required spacing / for live parts / downwards
-
10 mm(4)
Required spacing / for live parts / forwards
-
10 mm(5)
Required spacing / for live parts / upwards
-
10 mm(5)
Required spacing / with side-by-side mounting / at the side
-
0 mm(10)
Required spacing / with side-by-side mounting / downwards
-
10 mm(6)
Required spacing / with side-by-side mounting / forwards
-
10 mm(8)
Required spacing / with side-by-side mounting / upwards
-
10 mm(8)
Reset function
-
Manualandautomatic(2)
-
Manual,automaticandremote(4)
Reset Type
-
Manual(1)
-
Auto/Manual/Remote(11)
Residual current / of the semiconductor output / maximum
-
0.035 mA(1)
Response time / maximum
-
200 ms(1)
Response value residual current detection / at 50/60 Hz / typical
-
8 A(1)
Safety Integrity Level (SIL) / acc. to IEC 61508
-
3(1)
Shock resistance / at rectangular impulse / at AC
-
7,3g/5ms,4,7g/10ms(1)
Shock resistance / at rectangular impulse / at DC
-
10g/5ms,5g/10ms(2)
Shock resistance / with sine pulse / at AC
-
11,4g/5ms,7,3g/10ms(3)
Shock resistance / with sine pulse / at DC
-
15g/5ms,8g/10ms(1)
Size
-
82x110x108mm(94)
Size of contactor
-
S0(7)
-
S0,S2(1)
-
NEMAcontrollersize1(2)
-
NEMAcontrollersize0(3)
-
NEMAcontrollersize3(2)
-
S00(13)
-
S00,S0(2)
-
S00,S0,S2,S3(3)
-
S2,S3(10)
-
S2(5)
-
S3(2)
Size of the circuit-breaker
-
S00,S0,S2,S3(24)
-
S00,S0(2)
-
S0(1)
-
S2(3)
-
S3(2)
Size of the screwdriver tip
-
StandardscrewdriverSize2(2)
Special product feature
-
ESP200overloadrelay;Dualvoltagecoil(4)
-
ESP200overloadrelay(4)
-
Dualvoltagecoil(1)
Standard
-
UL E14900, cUL, CSA(12)
-
cUL, CSA(1)
-
UL Listed File E14900, CSA Certified File LR6535(80)
-
Yes(4)
-
RoHs, CSA, cUL, CE, GOST(94)
-
UL 508, UL 698, UL 1203, CSA Number C22.2 14-M, C22.2 No. 25, C22.2 No. 30, C/US UL File Number E76550, E81751, Class I, Division 1, Groups C, D, Class II, Division 1 And 2, Groups E, F, G, Class III(2)
Standard for wireless communication / IEEE 802.11
-
No(1)
Status display / AS-Interface / LED
-
LEDgreen(power):poweron;LEDyellow(seractive):RS232interfaceinoperation;LEDgreen/red(test):testmode(1)
Suitability for use
-
motorcircuitbreaker(14)
Suitability for use / Monitoring of floating sensors
-
Yes(1)
Suitability for use / opto-electronic protection device monitoring
-
Yes(1)
Suitability for use / safety switch
-
Yes(1)
Surge voltage resistance / of the auxiliary and control current circuit / rated value
-
4 kV(1)
Surge voltage resistance / rated value
-
6 kV(8)
-
4000 V(1)
Switch-on delay time / maximum
-
95 ms(1)
-
34 ms(1)
-
29 ms(1)
Switch-on delay time / minimum
-
19 ms(4)
-
26 ms(1)
Switching frequency
-
5 Hz(1)
T1 value / for proof test interval or service life / acc. to IEC 61508
-
20 a(5)
Temperature / of the conductor / for line-side / maximum permissible
-
75 C(3)
Temperature / of the conductor / for load-side outgoing feeder / maximum permissible
-
75 C(1)
Temperature / of the conductor / of the magnet coil / maximum permissible
-
75 C(3)
Temperature range / moved / min
-
-25 C(1)
Temperature range / stationary / max
-
85 C(1)
Temperature range / stationary / min
-
-40 C(1)
Tightening torque / for line-side / maximum
-
20 lbf.in(2)
-
275 lbf.in(1)
Tightening torque / for line-side / minimum
-
180 lbf.in(2)
-
120 lbf.in(1)
-
35 lbf.in(1)
Tightening torque / for auxiliary contacts / of the contactor / maximum
-
15 lbf.in(6)
Tightening torque / for auxiliary contacts / of the contactor / minimum
-
7 lbf.in(1)
-
10 lbf.in(4)
Tightening torque / for load-side outgoing feeder / maximum
-
220 lbf.in(1)
-
45 lbf.in(1)
-
120 lbf.in(1)
-
20 lbf.in(2)
-
24 lbf.in(1)
Tightening torque / for load-side outgoing feeder / minimum
-
180 lbf.in(1)
-
20 lbf.in(2)
-
200 lbf.in(1)
Tightening torque / for the magnet coil / maximum
-
10 lbf.in(1)
-
12 lbf.in(2)
Tightening torque / for the magnet coil / minimum
-
5 lbf.in(8)
Tightening torque / with screw-type terminals / minimum
-
2 N.m(2)
-
0.4 N.m(1)
Tightening torque [lbfin] / at overload relay / for auxiliary contacts / maximum
-
10 lbf.in(4)
Tightening torque [lbfin] / at overload relay / for auxiliary contacts / minimum
-
7 lbf.in(3)
Total current / maximum
-
12 A(1)
Trip CLASS
-
Class20(1)
-
Class5/10/20(factoryset)/30(2)
Trip time / at phase-loss / maximum
-
3 s(3)
Type
-
FVNR, Heavy Duty, Class 14(7)
-
Class SMF(3)
-
Standard, 1-Unit, Class SMF(1)
-
accessory(1)
-
Standard, Class MMS(1)
-
replacement contact kit(4)
-
Enclosed Accessory(1)
-
Pump Controller(4)
-
Motor Starter(7)
-
Class 87(1)
-
Non-Illuminated(1)
-
Manual Contactor(2)
-
Contactors(141)
Type of assignment
-
2(2)
-
continousoperationaccordingtoIEC60947-6-2(10)
-
Type1coordination(9)
Type of connectable conductor cross-sections / at AWG conductors / for auxiliary contacts
-
2x(20...16),2x(18...14),2x12(7)
-
2x(20...12)(5)
-
2x(20...16),2x(18...14)(1)
Type of connectable conductor cross-sections / at AWG conductors / for main contacts
-
2x(10...1/0),1x(10...2/0)(2)
Type of connectable conductor cross-sections / at AWG conductors / solid
-
1x(20...14),2x(18...16)(1)
Type of connectable conductor cross-sections / at AWG conductors / stranded
-
2x(14...10)(1)
-
1x(18...22)(1)
Type of connectable conductor cross-sections / finely stranded / with core end processing
-
1x(0.5...2.5mm),2x(0.5...1.0mm)(1)
Type of connectable conductor cross-sections / for auxiliary contacts / solid
-
2x(0.5...1.5mm),2x(0.75...2.5mm)(3)
-
2x(0.5...2.5mm),2x(2.5...4mm)(1)
Type of connectable conductor cross-sections / for main contacts / solid
-
1x(2.5...25mm)(1)
-
2x(2.5...50mm),1x(2.5...70mm)(2)
Type of connectable conductor cross-sections / for main contacts / stranded
-
1x(2.5...25mm)(2)
-
2x(2.5...50mm),1x(2.5...70mm)(2)
Type of connectable conductor cross-sections / solid
-
1x10mm,2x(1...2.5mm),2x(2.5...6mm)(2)
Type of disconnecting device
-
NoDisconnect(1)
-
Non-FusibleDisconnect30A(1)
Type of electrical connection
-
screw-typeterminals(4)
-
spring-loadedterminals(2)
-
Push-interminal(1)
-
cable(1)
Type of electrical connection / at input / for main current circuit
-
screw-typeterminals/tabterminals(1)
Type of electrical connection / at overload relay / for auxiliary contacts
-
screw-typeterminals(1)
Type of electrical connection / for auxiliary and control current circuit
-
screw-typeterminals(11)
-
spring-loadedterminals(4)
Type of electrical connection / for auxiliary contacts
-
screw-typeterminals(4)
Type of electrical connection / for load-side outgoing feeder
-
Screw-typeterminals(1)
Type of electrical connection / for main current circuit
-
screw-typeterminals(18)
-
plug-inwithoutterminals(1)
Type of electrical connection / for supply voltage infeed -> line-side
-
Boxlug(6)
-
Screw-typeterminals(1)
Type of electrical connection / of the magnet coil
-
screw-typeterminals(7)
Type of voltage
-
DC(1)
Type of voltage / of the control supply voltage
-
n.a.(3)
-
AC(37)
-
AC/DC(38)
-
DC(62)
Type of voltage / of the operating voltage
-
AC/DC(1)
Type of voltage supply / via input/output link master
-
No(1)
Vibration resistance
-
1...6Hz,15mm;20m/s,500Hz(43)
Vibration resistance / acc. to IEC 60068-2-6
-
5...500Hz:0.75mm(1)
Voltage Rating
-
120/240 VAC(5)
-
120@60Hz VAC(1)
-
240/480 VAC(2)
-
600 VAC(1)
-
120 V(8)
-
460V(2)
weight [lb]
-
113 lb(1)
-
6 lb(1)
Width
-
150 mm(1)
-
85 mm(2)
-
105 mm(2)
-
45 mm(6)
-
28 mm(2)
-
30 mm(16)
-
17.5 mm(1)
-
20 mm(1)
-
22.5 mm(1)
-
38 mm(1)
Width of the sensor
-
25 mm(1)
Width [in]
-
5.75 in(1)
-
10.5 in(1)
-
8 in(1)
-
12 in(3)
yielded mechanical performance [hp] / for three-phase AC motor / at 115 V / Rated value
-
2.000 hp(2)
Manufacturers
Products from this Category
Showing 2332 results
-
Appleton Electric #:AFA4327X12
Motor Starter Space Heater, Trip Type Standard, Approval UL 50/1203, Used On AEB Series Motor Starter, Power Rating 40 W, Standard Finish Corrosion Re...
Edwards #:APPLAFA4327X12[Call For Price] -
Appleton Electric #:AE0TT240215
Motor Starter, Type Full Voltage Non-Reversing Starter, Constructional Feature Explosionproof, Dust Ignitionproof, Watertight, Motor/Line Voltage 240 ...
Edwards #:APPLAE0TT240215[Call For Price] -
Appleton Electric #:AE1TT240750
Motor Starter, Type Full Voltage Non-Reversing Starter, Constructional Feature Explosionproof, Dust Ignitionproof, Watertight, Motor/Line Voltage 240 ...
Edwards #:APPLAE1TT240750[Call For Price] -
Appleton Electric #:AEOTT480315
Motor Starter, Type Full Voltage Non-Reversing Starter, Constructional Feature Explosionproof, Dust Ignitionproof, Watertight, Motor/Line Voltage 480 ...
Edwards #:APPLAEOTT480315[Call For Price] -
Appleton Electric #:AEOTT480520
Motor Starter, Type Full Voltage Non-Reversing Starter, Constructional Feature Explosionproof, Dust Ignitionproof, Watertight, Motor/Line Voltage 480 ...
Edwards #:APPLAEOTT480520[Call For Price] -
Appleton Electric #:AE0TT600515
Motor Starter, Type Full Voltage Non-Reversing Starter, Constructional Feature Explosionproof, Dust Ignitionproof, Watertight, Motor/Line Voltage 600 ...
Edwards #:APPLAE0TT600515[Call For Price] -
Appleton Electric #:AE0TM240315
Motor Starter, Type Full Voltage Non-Reversing Starter, Constructional Feature Explosionproof, Dust Ignitionproof, Watertight, Motor/Line Voltage 240 ...
Edwards #:APPLAE0TM240315[Call For Price] -
Appleton Electric #:N2D75FA-U1
Switch Control and Fire Alaram Station, Type Break Glass, Contact Voltage Rating 600 VAC, Contact Current Rating 10 Ampere, Contact Configuration 1NO ...
Edwards #:APPLN2D75FA-U1[Call For Price] -
Appleton Electric #:N1DC75-1MSW
Manual Mototr Starter, 1 Phase HP/Volts 1 HP at 120 to 240 VAC, Poles 1, Enclosure Type NEMA 3/4X/12, Hub Size 1/2 or 3/4, Conduit Entry Feed Through,...
Edwards #:APPLN1DC75-1MSW[Call For Price] -
Appleton Electric #:N1DC75-2MSW
Manual Mototr Starter, 1 Phase HP/Volts 1 HP at 120 to 240 VAC, Poles 2, Enclosure Type NEMA 3/4X/12, Hub Size 1/2 or 3/4, Conduit Entry Feed Through,...
Edwards #:APPLN1DC75-2MSW[Call For Price] -
Siemens Industry #:3RV1901-1AB1
SIDE-MOUNTED AUXILIARY SW.
Edwards #:SIEM3RV1901-1AB1[Call For Price] -
Siemens Industry #:3UF7112-1AA00-0
SIMOCODE PRO CUR/VOLT MEAS.MOD.,10-100A
Edwards #:SIEM3UF7112-1AA00-0[Call For Price] -
Siemens Industry #:3RV1902-1AB4
MSP UNDERVOLTAGE REL,24VDC,MSP S00-S3
Edwards #:SIEM3RV1902-1AB4[Call For Price] -
Siemens Industry #:17HP92BA1581
STARTER-COMBO,SZ3,N1,100A FSBL,120/240V
Edwards #:SIEM17HP92BA1581[Call For Price] -
Siemens Industry #:17HP92NA1581
STARTER-COMBO,SZ3,N12,100A FSBL,120/240V
Edwards #:SIEM17HP92NA1581[Call For Price] -
Siemens Industry #:17JP92BA1781
STARTER-COMBO,SZ4,N1,200A FSBL,120/240V
Edwards #:SIEM17JP92BA1781[Call For Price] -
Siemens Industry #:17JP92NA1781
STARTER-COMBO,SZ4,N12,200A FSBL,120/240V
Edwards #:SIEM17JP92NA1781[Call For Price] -
Siemens Industry #:17JP92WA1781
STARTER-COMBO,SZ4,N4S,200A FSBL,120/240V
Edwards #:SIEM17JP92WA1781[Call For Price] -
Appleton Electric #:N1DC75-30B
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type QOU, Trip Type Thermal, Volta...
Edwards #:APPLN1DC75-30B[Call For Price] -
Appleton Electric #:N1D75-15B
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type QOU, Trip Type Thermal, Volta...
Edwards #:APPLN1D75-15B[Call For Price]